(1) If the tests are OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
(2) If the fault continues:
- replace the related DEU-B 300RHxx (Ref. AMM TASK 23-73-47-000-001) and (Ref. AMM TASK 23-73-47-400-001).
**ON A/C 151-199,
B. If there is no maintenance message, but there is a fault in one or both of the operational tests for two or more handsets:
- make sure that at least one cabin door is open.
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close the CBs 156RH and 157RH.
- stop for approx. 120 s,
- do the operational tests again.
(1) If the tests are OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(2) If the fault continues:
- replace the related DEU-B 300RHx (Ref. AMM TASK 23-73-47-000-001) and (Ref. AMM TASK 23-73-47-400-001).
**ON A/C ALL
C. Install the removed DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
D. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 242
Aug 01/05 CES
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
TASK 23-73-00-810-866
FAP - No Control of the CIDS Cabin Systems
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- ATTENDANT PANEL-FORWARD (120RH)
- Light Module
- Audio Module
- Miscellaneous Module
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
23-73-00-810-838 FAP - Fault in the Forward Attendant Panel AMM 23-73-12-000-002 Removal of the Forward Attendant Panel (FAP) 120RH AMM 23-73-12-000-003 Removal of the Light Module AMM 23-73-12-000-004 Removal of the Audio Module AMM 23-73-12-000-005 Removal of the Miscellaneous Module AMM 23-73-12-400-002 Installation of the Forward Attendant Panel (FAP)
120RH
AMM 23-73-12-400-003 Installation of the Light Module
AMM 23-73-12-400-004 Installation of the Audio Module
AMM 23-73-12-400-005 Installation of the Miscellaneous Module
AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH)
AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
3. Fault Confirmation
__________________
A. Test
(1) Do the FAP test through the CFDS.
(2) Use the FAP to control some systems controlled through the FAP.
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
B. If the CFDS gives the maintenance message FWD ATTND PNL 120RH:
- do the trouble shooting for CFDS maintenance message FWD ATTND PNL 120RH (Ref. TASK 23-73-00-810-838).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 243
201-299, Aug 01/05 CES
C. If the CFDS gives no FWD ATTND PNL 120RH fault message and you cannot control the FAP controlled systems through the FAP:
- make sure, which FAP module is effected.
(1) If all FAP modules are effected:
- replace the ATTENDANT PANEL-FORWARD (120RH) (Ref. AMM TASK 23-73-12-000-002) and (Ref. AMM TASK 23-73-12-400-002).
(2) If not all FAP modules are effected:
- locate the faulty FAP Module
(a) If the Light Module is faulty:
- replace the Light Module (Ref. AMM TASK 23-73-12-000-003) and (Ref. AMM TASK 23-73-12-400-003).
(b) If the Audio Module is faulty:
1_ If the fault continues:
- replace the ATTENDANT PANEL-FORWARD (120RH) (Ref. AMM TASK
23-73-12-000-002) and (Ref. AMM TASK 23-73-12-400-002).
- replace the Audio Module (Ref. AMM TASK 23-73-12-000-004) and (Ref. AMM TASK 23-73-12-400-004).
1 If the fault continues:
_
- replace the ATTENDANT PANEL-FORWARD (120RH) (Ref. AMM TASK 23-73-12-000-002) and (Ref. AMM TASK 23-73-12-400-002).