3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. Test
(1) Open these CBs:
- 49VU: 153RH CIDS/DEU B/ESS
- 121VU:162RH CIDS/DEU B/NORM,
(2) Wait for 10 s and close the CBs 153RH and 162RH.
(3) Do the CIDS BITE test through the CFDS (Ref. AMM TASK 23-73-00-740-005).
(4) Examine the related AIP for an incorrect indication or no indication.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 260
Aug 01/05R CES
R **ON A/C 106-149, 301-399, 401-499,
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
(2) Examine the related AIP for an incorrect indication or no indication.
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble
shooting procedure related to the maintenance message.
B. If there is no maintenance message, but there is a fault in the AIP:
- replace the related AIP (320RHxx) (Ref. AMM TASK 23-73-22-000-001) and (Ref. AMM TASK 23-73-22-400-001).
(1) If the fault continues:
- replace the releted 300RHxx (Ref. AMM TASK 23-73-47-000-001) and (Ref. AMM TASK 23-73-47-400-001) (Ref. ASM 23-73/06).
(a) If the fault continues:
- do a check of the wiring between: the related DEU-B (300RHxx) connector C/15 and the AIP (320RHxx) connector A/4, the related DEU-B (300RHxx) connector C/16 and the AIP (320RHxx) connector A/5, (Ref. ASM 23-73/06).
C. Do the test given in Para. 3.A.
TASK 23-73-00-810-872
PA - No Audio Signals from one or two Loudspeakers in Series
1. Possible Causes
_______________
- loudspeakers
- DEU-A (200RHxx)
- wiring
- PISA 602RHxx
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-710-036 Operational Test of the Loudspeaker via MCDU AMM 23-73-00-740-005 BITE Test of the Cabin Intercommunication Data System (CIDS) through the CFDS AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin Intercommunication Data System (CIDS) via the CFDS AMM 23-73-41-000-001 Removal of the Passenger Interface and Supply Adapter (PISA) AMM 23-73-41-400-001 Installation of the Passenger Interface and Supply
Adapter (PISA) AMM 23-73-46-000-001 Removal of the Decoder/Encoder Unit (DEU) A 200RH AMM 23-73-46-400-001 Installation of the Decoder/Encoder Unit (DEU) A
200RH
AMM 23-73-51-000-001 Removal of the Loudspeaker
AMM 23-73-51-400-002 Installation of the Loudspeaker
ASM 23-73/13
ASM 23-73/14
ASM 23-73/15
ASM 23-73/16
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
A. Test
(1) Do the CIDS BITE test through the CFDS (Ref. AMM TASK 23-73-00-740-005).
(2) Do the CIDS1 LOUDSPEAKER test through the CFDS.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 262
Aug 01/05R CES
R **ON A/C 106-149, 301-399, 401-499,
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
(2) Do the CIDS LOUDSPEAKER test via the CFDS (Ref. AMM TASK 23-73-00-710-036).
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble
shooting procedure related to the maintenance message.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
B. If there is no maintenance message, but there is a fault in one or two loudspeakers in series:
- replace the related loudspeakers (Ref. AMM TASK 23-73-51-000-001) and (Ref. AMM TASK 23-73-51-400-002).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(58)