- make sure that at least one cabin door is open,
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU:151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the CIDS2/PTP test.
(1) If the CIDS2/PTP test does not give the message NO P & TP DATA:
- install a new DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B204
201-299, Aug 01/05R CES
**ON A/C 151-199,
B. If the CIDS1/PTP test gives the maintenance message NO P & TP DATA:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- stop for approx. 120 s,
- do the CIDS2/PTP test.
(1) If the CIDS2/PTP test does not give the message NO P & TP DATA:
- install a new DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-400-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. If the fault continues:
- replace the PROGRAMMING AND TEST PANEL (110RH) (Ref. AMM TASK 23-73-18-000-001) and (Ref. AMM TASK 23-73-18-400-001).
D. If the fault continues:
- do a check and repair the wiring between: CB 161RH and PTP connector A/17, DIR-CIDS (101RH) connector AA/F12 and PTP (110RH) connector A/1, DIR_CIDS (101RH) connector AA/G12 and PTP (110RH) connector A/2, DIR-CIDS (102RH) connector AA/F12 and PTP (110RH) connector A/6, DIR-CIDS (102RH) connector AA/G12 and PTP (110RH) connector A/7, DIR-CIDS (101RH) connector AA/J12 and PTP (100RH) connector A/4, DIR-CIDS (101RH) connector AA/K12 and PTP (110RH) connector A/5, DIR-CIDS (102RH) connector AA/J12 and PTP (110RH) connector A/4, DIR-CIDS (102RH) connector AA/K12 and PTP (110RH) connector A/5, PTP (110RH) connector A/3 and GND, PTP (110RH) connector A/8 and GND, PTP (110RH) connector A/16 and GND (Ref. ASM 23-73/09).
E. Install the removed DIR-CIDS (101RH) (Ref. AMM TASK 23-73-34-400-001).
F. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B205
201-299, Aug 01/05R
CES
TASK 23-73-00-810-860
CAM - Fault in the Cabin Assignment Modul Data Transfer
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- CAM
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-005 BITE Test of the Cabin Intercommunication Data System
(CIDS) through the CFDS AMM 23-73-19-000-001 Removal of the Cabin Assignment Module (115RH) AMM 23-73-19-400-001 Installation of the Cabin Assignment Module (115RH) AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
3. Fault Confirmation
__________________
A. Test
(1) Do the CIDS BITE test through the CFDS (Ref. AMM TASK 23-73-00-740-005).
(2) Open this CB for approx. 10 s then close it again:
- 121VU: 161RH CIDS/PROG AND/TST PNL.
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.