_
- replace the C/B-CAPT/LOUD/SPKR (5WW).
(2) If the circuit breaker is open:
- close it.
(a) If it opens again:
- replace the LOUD SPEAKER-CAPT (7WW) (Ref. AMM TASK 31-53-21-000-001) and (Ref. AMM TASK 31-53-21-400-001).
1 If the fault continues:
_
- do a check for a short to ground at the wiring between the Captain loud speaker (7WW) and the circuit breaker (5WW) (Ref. ASM 31-51/01).
a If there is a short to ground:
_
- repair the above wiring. b If there is no short to ground:
_
- replace the C/B-CAPT/LOUD/SPKR (5WW).
(b) If the circuit breaker stays closed and the fault continues:
- replace the LOUD SPEAKER-CAPT (7WW) (Ref. AMM TASK 31-53-21-000-001) and (Ref. AMM TASK 31-53-21-400-001).
C. Do the test given in Para. 3.
TASK 23-51-00-810-841
Failure of the Loud Speaker Card 2 Circuit
1. Possible Causes
_______________
- AMU (1RN)
- LOUD SPEAKER-F/O (8WW)
- POT-LOUD SPEAKER, F/O (15RN2)
- wiring
- C/B-F/O/LOUD/SPKR (4WW)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
IPC 235108
AMM 23-51-00-710-001 Operational Test of the Audio Management
AMM 23-51-34-000-001 Removal of the Audio Management Unit (AMU) (1RN)
AMM 23-51-34-400-001 Installation of the Audio Management Unit (AMU) (1RN)
AMM 31-53-21-000-001 Removal of the Loudspeakers (7WW,8WW)
AMM 31-53-21-400-001 Installation of the Loudspeakers (7WW,8WW)
ASM 23-51/02
ASM 31-51/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the audio management system (Ref. AMM TASK 23-51-00-710-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU CAPT/LOUD/SPKR 5WW F10 121VU EIS/F/O/LOUD/SPKR 4WW P08
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-51-00∞∞∞∞∞∞∞∞∞∞Page 261
Aug 01/01 CES
B. If the loud speaker at the First Officer station does not operate: R - do a check of the circuit breaker (4WW) status.
(1) If the circuit breaker is closed:
- do a check for 28VDC at pin A/A of the First Officer loud speaker (8WW) (Ref. ASM 31-51/01).
(a) If there is 28VDC:
- replace the AMU (1RN) (Ref. AMM TASK 23-51-34-000-001) and (Ref. AMM TASK 23-51-34-400-001).
1 If the fault continues:
_
- replace the POT-LOUD SPEAKER, F/O (15RN2) (Ref. IPC 235108).
2 If the fault continues:
_
- replace the LOUD SPEAKER-F/O (8WW) (Ref. AMM TASK 31-53-21-000-001) and (Ref. AMM TASK 31-53-21-400-001).
3 If the fault continues:
_
- do a check of the wiring between AMU (1RN) pins AA/11J, 11H and First Officer loud speaker (8WW) pins A/C, G (Ref. ASM 23-51/02).
a If there is no continuity:
_ - repair the above wiring.
b If there is continuity:
_
- do a check of the wiring between: . AMU (1RN) pin AA/11G and First Officer loud speaker potentiometer (15RN2) pin A/3 . First Officer loud speaker (8WW) pin A/F and First Officer loud speaker potentiometer (15RN2) pin A/1
- repair the above faulty wiring.
(b) If there is no 28VDC:
- do a check for a ground signal at pin A/B of the First Officer loud speaker (8WW) (Ref. ASM 31-51/01).
1 If there is no ground signal:
_
- repair the wiring between the First Officer loud speaker (8WW) pin A/B and the ground terminal (Ref. ASM 31-51/01).
2 If there is a ground signal:
_
- do a check of the wiring between the First Officer loud speaker (8WW) pin A/A and the circuit breaker (4WW) (Ref. ASM 31-51/01).
a If there is no continuity:
_ - repair the above wiring.
b If there is continuity:
_
- replace the C/B-F/O/LOUD/SPKR (4WW).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-51-00∞∞∞∞∞∞∞∞∞∞Page 262
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(22)