- disconnect the electrical connector from the DEU CONNECTION BOX (308RH1) (Ref. ASM 23-73/06).
- do a check of the wiring (continuity-check) between: DIR-CIDS (101RH) connector AA/D14 and the DEU CONNECTION BOX (308RH1) connector pin A/2, DIR-CIDS (101RH) connector AA/E14 and the DEU CONNECTION BOX (308RH1) connector pin A/1.
1 If there is no continuity:
_
- repair the wiring between the DIR-CIDS (101RH) and the connector DEU CONNECTION BOX (308RH1) (Ref. ASM 23-73/06).
2 If there is continuity:
_
- do a check of the wiring (continuity-check) between: DEU CONNECTION BOX (308RH1) pin A/1 and pin A/9 , DEU CONNECTION BOX (308RH1) pin A/2 and pin A/10.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A267
Aug 01/05 CES b If there is continuity:
a_ If there is no continuity:
- install a new DEU CONNECTION BOX (308RH1) (Ref. AMM TASK
23-73-42-000-001) and (Ref. AMM TASK 23-73-42-400-001).
_
- reconnect the connector to the DEU CONNECTION BOX (308RH1).
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops: DIR-CIDS (101RH) and DEU CONNECTION BOX (308RH3), DIR-CIDS (101RH) and DEU CONNECTION BOX (308RH5), DIR-CIDS (101RH) and DEU TERMINATION BOX (309RH1).
(7) If the resistance (line to line) is less than 80 ohms (short circuit):
- remove the DECODER/ENCODER UNIT B (300RH7) (Ref. AMM TASK 23-73-47-000-001).
- do a check for a short circuit again.
(a) If there is no short circuit:
- install a new DECODER/ENCODER UNIT B (300RH7) (Ref. AMM TASK 23-73-47-400-001).
(b) If there is a short circuit:
- install the removed DECODER/ENCODER UNIT B (300RH7) (Ref. AMM TASK 23-73-47-400-001).
- diconnect the electrical connector from the DEU TERMINATION BOX (309RH1) (Ref. ASM 23-73/06),
- do a check for a short circuit again.
1 If there is a short circuit:
_
- reconnect the electrical connector to the DEU TERMINATION BOX (309RH1),
- do the steps 4. B. (7) again for the subsequent DEU(s) and DEU CONNECTION/ TERMINATION BOX(es) until the maintenance message stops for: (Ref. ASM 23-73/06) DEU CONNECTION BOX (308RH3), DEU CONNECTION BOX (308RH5), DEU-B (300RH1) and DEU CONNECTION BOX (308RH1),
2 If there is no short circuit:
_
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 (Ref. ASM 23-73/06)
a If there is a short circuit:
_
- repaire the wiring between the related DEU CONNECTION BOX 308RHxx and the DEU CONNECTION/ TERMINATION BOX(es) 308RHxx/309RHxx (Ref. ASM 23-73/06).
b If there is no short circuit:
_
- install a new DEU TERMINATION BOX (309RH1) (Ref. AMM TASK 23-73-48-400-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. Installation of removed components
- Install the removed DIR-CIDS, 1 (101RH) and DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-400-001).
- Install all the removed DEU-B (300RHxx) (Ref. AMM TASK 23-73-47-400-001).
- Reconnect all the DEU-mount-connectors to the related DEU-mounts (2011VUxx/2015VUx) (Ref. AMM TASK 23-73-48-400-001).
R **ON A/C 106-149, 301-399, 401-499,
C. Installation of removed components
- Install the removed DIR-CIDS, 1 (101RH) and DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-400-001).
- Install all the removed DEU-B (300RHxx) (Ref. AMM TASK 23-73-47-400-001).
- Reconnect all the DEU CONNECTION/ TERMINATION BOX-connectors to the related DEU CONNECTION/ TERMINATION BOX (Ref. ASM 23-73/06).
- Make sure that all previously opened CBs are closed.
**ON A/C ALL
D. Do the test given in Para. 3.A.
TASK 23-73-00-810-837
CIDS - Fault in the CIDS MID BUS R
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- DIR-CIDS, 2 (102RH)
- DEU-B (300RH6)
- DEU-B (300RH4)
- DEU-B (300RH8)
- DEU TERMINATION BOX (309RH2)
- DEU CONNECTION BOX (308RH6)
- DEU CONNECTION BOX (308RH2)
- DEU CONNECTION BOX (308RH4)
- DEU mount 2015VU2
- DEU mount 2011VU4
- wiring
- DEU mount 2011VU2
2. Job Set-up Information
______________________
A. Referenced Information