- make sure that at least one cabin door is open,
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU:151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the CIDS2 BITE test.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B206
201-299, Aug 01/05R CES
(1) If CIDS2 BITE test does not give the maintenance message NO CAM DATA:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- replace the CAM (Ref. AMM TASK 23-73-19-000-001) and (Ref. AMM TASK 23-73-19-400-001).
**ON A/C 151-199,
B. If the CIDS BITE test gives the maintenance message NO CAM DATA:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close the CBs 156RH and 157RH.
- stop for approx. 120 s,
- do the CIDS2 BITE test.
(1) If CIDS2 BITE test does not give the maintenance message NO CAM DATA:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- replace the CAM (Ref. AMM TASK 23-73-19-000-001) and (Ref. AMM TASK 23-73-19-400-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. Install the removed DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
D. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B207
201-299, Aug 01/05 CES
**ON A/C ALL
TASK 23-73-00-810-839
Sign - Fault in the NO SMOKING Sign
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- NS-FSB sign lamp
- wiring
- PCB 2038VU
- DEU-A
- NS-FSB sign
- PISA
- NO SMOKING switch
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-710-034
AMM 23-73-00-710-035
AMM 23-73-00-740-010
AMM 23-73-34-000-001
AMM 23-73-34-400-001
AMM 23-73-41-000-001
AMM 23-73-41-400-001
AMM 23-73-46-000-001
AMM 23-73-46-400-001
AMM 23-73-49-000-001
AMM 23-73-49-400-001
AMM 23-73-63-000-001
AMM 23-73-63-000-002
AMM 23-73-63-400-001
Sign Lamps Test from the MCDUOperational Test of the Cabin LED Lamps via MCDUInterface and Power-Up Test of the Cabin Intercommunication Data System (CIDS) via the CFDSRemoval of the CIDS Director (101RH,102RH)Installation of the CIDS Director (101RH,102RH)Removal of the Passenger Interface and Supply Adapter (PISA)Installation of the Passenger Interface and Supply Adapter (PISA)Removal of the Decoder/Encoder Unit (DEU) A 200RHInstallation of the Decoder/Encoder Unit (DEU) A 200RHRemoval of the Printed Circuit Board (PCB) with the Bulbs or LEDsInstallation of the Printed Circuit Board (PCB) with the Bulbs or LEDsRemoval of the No Smoking/Fasten Seat Belt (NS/FSB) Signs in the PSIU and the C/B panels 2000VU and 2001VU.Removal of the No Smoking/Fasten Seat Belt (NS/FSB) Signs in certain areas of the cabin.Installation of the No Smoking/Fasten Seat Belt (NS/FSB) Signs in the PSIU and the C/B panels 2000VU and 2001VU.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B208
Aug 01/05R
CES -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------