- do the test again (start with step 4.).
(1) If the ECAM message CIDS 1&2 FAULT is not shown and the CFDS message CIDS2 is not shown, but the CIDS2 is in operation (ACT mode):
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring if necessary between the: CB 151RH and DIR-CIDS, 1 (101RH) connector AC/4, CB 151RH and DIR-CIDS, 1 (101RH) connector AB/E12, CB 156RH and DIR-CIDS, 2 (102RH) connector AB/E12, CB 156RH and DIR-CIDS, 2 (102RH) connector AC/4, DIR-CIDS, 1 (101RH) connector AC/6 and GND, DIR-CIDS, 1 (101RH) connector AB/C12 and DIR-CIDS, 2 (102RH) connector AB/F12 (Ref. ASM 23-73/06).
**ON A/C 151-199,
C. If the fault is confirmed and CIDS1 (ACT) is shown on the CFDS:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR 1/ESS
49VU: 157RH (G02) COM DIR 2/ESS
121VU: 151RH (M06) CIDS/DIR1/NORM
121VU: 156RH (M07) CIDS/DIR2/NORM
- wait for approx. 10 s and close 156RH and 157RH,
- stop for approx. 120 s,
- do the test again.
(1) If the ECAM message CIDS 1&2 FAULT and CFDS message DIRECTOR (CIDS2 (ACT)) come on:
- install a new DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001)
- do the test again.
(a) If the fault continues:
- do a check and repair the wiring if necessary between the: CB 156RH and DIR-CIDS2 connector AB/E12, CB 156RH and DIR-CIDS2 connector AC/4 (Ref. ASM 23-73/06). DIR-CIDS2 connector AC pin 6 and GND.
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001),
- do the test again.
1 If the fault continues:
_
- do a check and repair the wiring between the: CB 151RH and DIR-CIDS1 connector AB/E12,
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 151-199, 301-399, 401-499, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 205
Aug 01/05 CES
CB 151RH and DIR-CIDS1 connector AC/4,
DIR-CIDS1 connector AC/6 and GND,
DIR-CIDS1 connector AB/C12 and DIR-CIDS2 connector AB/F12
(Ref. ASM 23-73/06).
(b) If the ECAM message CIDS 1&2 FAULT do not come on and the CFDS message CIDS2 (ACT) come on:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001),
- do the test again.
1 If the fault continues:
_
- do a check and repair the wiring between the: CB 151RH and DIR-CIDS1 connector AB/E12, CB 151RH and DIR-CIDS1 connector AC/4, DIR-CIDS1 connector AC/6 and GND, DIR-CIDS1 connector AB/C12 and DIR-CIDS2 connector AB/F12 (Ref. ASM 23-73/06).
D. If the fault is confirmed and CIDS2 (ACT) is shown on the CFDS:
- replace DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001),
- do the test again (start with step 4.).
(1) If the ECAM message CIDS 1&2 FAULT is not shown and the CFDS message CIDS2 DIRECTOR is not shown, but the CIDS2 is in operation (ACT mode):
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring if necessary between the: CB 151RH and DIR-CIDS1 connector AC/4, CB 151RH and DIR-CIDS1 connector AB/E12, CB 156RH and DIR-CIDS2 connector AB/E12, CB 156RH and DIR-CIDS2 connector AC/4, DIR-CIDS1 connector AC/6 and GND, DIR-CIDS1 connector AB/C12 and DIR-CIDS2 connector AB/F12 (Ref. ASM 23-73/06).
**ON A/C ALL
E. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 206
Aug 01/05R CES
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
TASK 23-73-00-810-881
CIDS - No CIDS Function in 50% of the Cabin
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- DEU-A 200RH
- wiring