- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001),
- do the test again.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 202
Aug 01/05R CES
1 If the fault continues:
_
- do a check and repair the wiring between the: CB 151RH and DIR-CIDS1 connector AB/E12, CB 151RH and DIR-CIDS1 connector AC/4, DIR-CIDS1 connector AC/6 and GND, DIR-CIDS1 connector AB/C12 and DIR-CIDS2 connector AB/F12 (Ref. ASM 23-73/06).
(b) If the ECAM message CIDS 1&2 FAULT do not come on and the CFDS message CIDS2 (ACT) come on:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001),
- do the test again.
1 If the fault continues:
_
- do a check and repair the wiring between the: CB 151RH and DIR-CIDS1 connector AB/E12, CB 151RH and DIR-CIDS1 connector AC/4, DIR-CIDS1 connector AC/6 and GND, DIR-CIDS1 connector AB/C12 and DIR-CIDS2 connector AB/F12 (Ref. ASM 23-73/06).
D. If the fault is confirmed and CIDS2 (ACT) is shown on the CFDS:
- replace DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001),
- do the test again.
(1) If the ECAM message CIDS 1&2 FAULT is not shown and the CFDS message CIDS2 DIRECTOR is not shown, but the CIDS2 is in operation (ACT mode):
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring if necessary between the: CB 151RH and DIR-CIDS1 connector AB/E12, CB 151RH and DIR-CIDS1 connector AC/4, CB 151RH and DIR-CIDS2 connector AB/E12, CB 151RH and DIR-CIDS2 connector AC/4, DIR-CIDS1 connector AC/6 and GND, DIR-CIDS1 connector AB/C12 and DIR-CIDS2 connector AB/F12 (Ref. ASM 23-73/06).
R **ON A/C 106-149, 301-399, 401-499,
C. If the fault is confirmed and DIR1 ACTIVE is shown on the CFDS:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH - COM/CIDS/DIR ESS/1
49VU: 157RH - COM/CIDS/DIR ESS/2
49VU: 15WH - AIR COND/CIDS/SDF/DIR 1 ESS
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 201-299, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 203
301-399, 401-499, Aug 01/05 CES
49VU: 18WH - AIR COND/CIDS/SDF/DIR 2 ESS
120VU: 151RH - COM NAV/CIDS/DIR/NORM/1
120VU: 156RH - COM NAV/CIDS/DIR/NORM/2
122VU: 14WH - AIR COND/CIDS/SDF/DIR NORM/2
122VU: 17WH - AIR COND/CIDS/SDF/DIR NORM/1
- wait for approx. 10 s and close 156RH, 157RH, 14WH and 18WH
- stop for approx. 120 s,
- do the test again.
(1) If the ECAM message CIDS 1&2 FAULT and CFDS message 237334 DIR2(102RH) DIR1 ACTIVE come on:
- install a new DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-000-001) and (Ref. AMM TASK 23-73-34-400-001)
- do the test again.
(a) If the fault continues:
- do a check and repair the wiring if necessary between the: CB 156RH and DIR-CIDS, 2 (102RH) connector AB/E12, CB 156RH and DIR-CIDS, 2 (102RH) connector AC/4 (Ref. ASM 23-73/06). DIR-CIDS, 2 (102RH) connector AC pin 6 and GND.
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001),
- do the test again.
1 If the fault continues:
_
- do a check and repair the wiring between the: CB 151RH and DIR-CIDS, 1 (101RH) connector AB/E12, CB 151RH and DIR-CIDS, 1 (101RH) connector AC/4, DIR-CIDS, 1 (101RH) connector AC/6 and GND, DIR-CIDS, 1 (101RH) connector AB/C12 and DIR-CIDS, 2 (102RH) connector AB/F12 (Ref. ASM 23-73/06).
(2) If the ECAM message CIDS 1&2 FAULT do not come on and the CFDS message CIDS2, DIR2 ACTIVE come on:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001),
- do the test again.
(a) If the fault continues:
- do a check and repair the wiring between the: CB 151RH and DIR-CIDS, 1 (101RH) connector AB/E12, CB 151RH and DIR-CIDS, 1 (101RH) connector AC/4, DIR-CIDS, 1 (101RH) connector AC/6 and GND, DIR-CIDS, 1 (101RH) connector AB/C12 and DIR-CIDS, 2 (102RH) connector AB/F12 (Ref. ASM 23-73/06).
D. If the fault is confirmed and DIR2 ACTIVE is shown on the CFDS: