(2) Open this CB for approx. 10 s and then close it again:
- 121VU: 161RH CIDS/PROG AND/TST PNL.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B201
Aug 01/05R
CES
R **ON A/C 106-149, 301-399, 401-499,
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS (Ref. AMM TASK 23-73-00-740-010).
**ON A/C ALL
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
**ON A/C 001-049, 051-099, 101-105, 201-299,
B. If the CIDS BITE test gives the maintenance message CAM:
- remove the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001),
- make sure that at least one cabin door is open,
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU:151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the CIDS2 BITE test.
(1) If the CIDS2 BITE test does not give the maintenance message CAM:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- replace the CAM (Ref. AMM TASK 23-73-19-000-001) and (Ref. AMM TASK 23-73-19-400-001).
1 If the fault continues:
_
- replace the PROGRAMMING AND TEST PANEL (110RH) (Ref. AMM TASK 23-73-18-000-001) and (Ref. AMM TASK 23-73-18-400-001).
R **ON A/C 106-149, 301-399, 401-499,
B. If the test confirms the fault:
- replace the MODULE-CABIN ASSIGNMENT (115RH) (Ref. AMM TASK 23-73-19-000-002) and (Ref. AMM TASK 23-73-19-400-002).
(1) If the fault continues:
- install a new FAP (120RH) (Ref. AMM TASK 23-73-12-000-007) and (Ref. AMM TASK 23-73-12-400-007).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page B202
Aug 01/05 CES
**ON A/C 151-199,
B. If the CIDS BITE test gives the maintenance message CAM:
- make sure that at least one cabin door is open,
- open these CBs: 49VU: 150RH (G01) COM DIR ESS/1 49VU: 157RH (G02) COM DIR ESS/2 121VU:151RH (M06) CIDS/DIR NORM/1 121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10 s and close the CBs 156RH and 157RH.
- stop for approx. 120 s,
- do the CIDS2 BITE test.
(1) If the CIDS2 BITE test does not give the maintenance message CAM:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
(a) If the fault continues:
- replace the CAM (Ref. AMM TASK 23-73-19-000-001) and (Ref. AMM TASK 23-73-19-400-001).
1_ If the fault continues:
- replace the PROGRAMMING AND TEST PANEL (110RH) (Ref. AMM
TASK 23-73-18-000-001) and (Ref. AMM TASK 23-73-18-400-001).
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
C. Install the removed DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001). **ON A/C ALL
D. Do the test given in Para. 3.A.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
TASK 23-73-00-810-859
PTP - Fault in the Programming and Test Panel Data Transfer
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- PROGRAMMING AND TEST PANEL (110RH)
- wiring