**ON A/C 001-049, 051-099, 101-105, 201-299,
B. If the CIDS BITE test result is no fault message, but you cannot operate the CIDS related systems:
- remove the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001),
- make sure that at least one cabin door is open.
- close these CBs:
49VU: 150RH (G02) CIDS/DIR 1 & 2/ESS
121VU: 151RH (M05) CIDS/DIR 1 & 2/NORM,
- stop for approx. 120 s,
- do the CIDS BITE test again (start with step 4.) and operate some CIDS related cabin systems.
(1) If there is no failure message and the related cabin systems are OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001)
(2) If there is a failure message and the related cabin systems are not OK:
- refer to the related trouble shooting procedure in the applicable Page Block 101.
R **ON A/C 106-149, 301-399, 401-499,
B. If the CIDS Interface and Power-Up test result is no fault message, but you cannot operate the CIDS related systems:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM/CIDS/DIR ESS/1
49VU: 157RH (G02) COM/CIDS/DIR ESS/2
49VU: 15WH (C06) AIR COND/CIDS/SDF/DIR1 ESS
49VU: 18WH (H02) AIR COND/CIDS/SDF/DIR2 ESS
120VU: 151RH (M05) COM NAV/CIDS/DIR NORM/1
120VU: 156RH (M07) COM NAV/CIDS/DIR NORM/2
122VU: 14WH (T18) AIR COND/CIDS/SDF/DIR NORM/2
122VU: 17WH (T17) AIR COND/CIDS/SDF/DIR NORM/1
- wait for approx. 10s and close the CBs 156RH, 157RH, 14WH and 18WH
- stop for approx. 120 s,
- do the CIDS POWER-UP test again (start with step 4.) and operate some CIDS related cabin systems.
(1) If there is no failure message and the related cabin systems are OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001)
(2) If there is a failure message and the related cabin systems are not OK:
- refer to the related trouble shooting procedure in the applicable Page Block 101.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 201-299, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 224
301-399, 401-499, Aug 01/05 CES
**ON A/C 151-199,
B. If the CIDS BITE test result is no fault message, but you cannot operate the CIDS related systems:
- make sure that at least one cabin door is open,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2,
- wait for approx. 10s and close the CBs 156RH and 157RH,
- stop for approx. 120 s,
- do the CIDS BITE test again (start with step 4.) and operate some CIDS related cabin systems.
(1) If there is no failure message and the related cabin systems are OK:
- install a new DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001)
(2) If there is a failure message and the related cabin systems are not OK:
- refer to the related trouble shooting procedure in the applicable Page Block 101.
**ON A/C ALL
C. Install the removed DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-400-001).
D. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page 225
Aug 01/05R
CES
TASK 23-73-00-810-862
PA - No PA/Cabin Interphone from Cockpit Boomset/Mike
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- cockpit boomset/mike
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
23-51-00-810-835 Loss of the Transmission from the Captain Boomset AMM 23-51-00-740-002 BITE Test of the Audio System AMM 23-73-00-710-005 Operational Test of the Passenger Address (PA) System AMM 23-73-00-740-005 BITE Test of the Cabin Intercommunication Data System
(CIDS) through the CFDS
AMM 23-73-00-740-010 Interface and Power-Up Test of the Cabin
Intercommunication Data System (CIDS) via the CFDS AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH) AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH) ASM 23-73/02 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(44)