1 If there is no continuity:
_
- repair the wiring between the DIR-CIDS (101RH) and the connector 7213VC3 (Ref. ASM 23-73/06).
2 If there is continuity:
_
- do a check of the wiring (continuity-check) between: DEU mount 2010VU3 pin A/1 and pin A/9 , DEU mount 2010VU3 pin A/2 and pin A/10.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A218
Aug 01/05 CES a If there is no continuity:
_
- install a new DEU mount 2010VU3 (Ref. AMM TASK 23-73-48-000-001) and (Ref. AMM TASK 23-73-48-400-001)
b If there is continuity:
_
- reconnect the connector 7213VC3 to the DEU mount 2010VU3 (Ref. AMM TASK 23-73-48-400-001)
- do the steps 4. B. (6) again for the subsequent DEU mounts until the maintenance message stops: DIR-CIDS (101RH) and DEU mount 2010VU7/connector 7213VC7, DIR-CIDS (101RH) and DEU mount 2010VU11/connector 7213VC11, DIR-CIDS (101RH) and DEU mount 2010VU17/connector 7213VC17, DIR-CIDS (101RH) and DEU mount 2010VU21/connector 7213VC21, DIR-CIDS (101RH) and DEU mount 2014VU3/connector 7253VC3.
(7) If the resistance (line to line) is less than 80 ohms (short circuit):
- remove the DEU-A (200RH25) (Ref. AMM TASK 23-73-46-000-001).
- do a check for a short circuit again.
(a) If there is no short circuit:
- install a new DEU-A (200RH25) (Ref. AMM TASK 23-73-46-400-001).
(b) If there is a short circuit:
- install the removed DEU-A (200RH25) (Ref. AMM TASK 23-73-46-400-001).
- diconnect the electrical connector 7253VC3 from the DEU mount 2014VU3 (Ref. ASM 23-73/06),
- do a check for a short circuit again.
1 If there is a short circuit:
_
- reconnect the electrical connector to the DEU mount 2014VU3 (Ref. AMM TASK 23-73-48-400-001),
- do the steps 4. B. (7) again for the subsequent DEUs and DEU mounts until the maintenance message stops: (Ref. ASM 23-73/06) DEU-A (200RH21) and DEU mount 2010VU21, DEU-A (200RH17) and DEU mount 2010VU17, DEU-A (200RH11) and DEU mount 2010VU11, DEU-A (200RH7) and DEU mount 2010VU7, DEU-A (200RH3) and DEU mount 2010VU3.
2 If there is no short circuit:
_
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 (Ref. ASM 23-73/06)
a If there is a short circuit:
_
- repaire the wiring between the related DEU mount 2010VUxx and the DEU mount 2014VUxx/2010VUxx (Ref. ASM 23-73/06).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A219
Aug 01/05 CES **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
b_ If there is no short circuit:
- install a new DEU mount 2014VU3 (Ref. AMM TASK 23-73-48-
400-001).
C. Installation of removed components
- Install the removed DIR-CIDS, 1 (101RH) and DIR-CIDS, 2 (102RH) (Ref. AMM TASK 23-73-34-400-001).
- Install all the removed DEU-A (200RHxx) (Ref. AMM TASK 23-73-46-400-001).
- Reconnect all the DEU-mount-connectors to the related DEU-mounts (2010VUxx/2014VUx) (Ref. AMM TASK 23-73-48-400-001).
D. Do the test given in Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞23-73-00∞∞∞∞∞∞∞∞∞∞Page A220
201-299, Aug 01/05 CES
**ON A/C ALL
TASK 23-73-00-810-834
CIDS - Fault in CIDS TOP BUS 1 R
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- DIR-CIDS, 2 (102RH)
- DEU-A (200RH24)
- DEU-A (200RH20)
- DEU-A (200RH16)
- DEU-A (200RH12)
- DEU-A (200RH8)
- DEU-A (200RH4)
- DEU-A (200RH14)
- DEU-A (200RH2)
- DEU TERMINATION BOX (209RH2)
- DEU CONNECTION BOX (208RH14)
- DEU CONNECTION BOX (208RH12)
- DEU CONNECTION BOX (208RH8)
- DEU CONNECTION BOX (208RH4)
- DEU CONNECTION BOX (208RH2)
- DEU-A (200RH26)
- DEU-A (200RH22)
- DEU-A (200RH18)
- DEU-A (200RH10)
- DEU-A (200RH6)
- DEU CONNECTION BOX (208RH6)
- DEU mount 2014VU2
- DEU mount 2010VU20 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯2(82)