 Cabin Emergency Lighting - Schematic
 Figure 010

R 1EFF : 001-049, 101-105, 201-209, 1 33-51-00Page 89 1 1 Aug 01/05 1 1 1CES 1


 Cabin Emergency Lighting - Schematic
 Figure 010A 
R 1EFF :  051-099,  1  33-51-00 Page 90 
1  1  Aug 01/05
 1  1
 1CES  1

 

 Cabin Emergency Lighting - Schematic
 Figure 010B 
R 1EFF :  151-158,  1  33-51-00 Page 91 
1  1  Aug 01/05
 1  1
 1CES  1

 

 Lavatory Auxiliary Lights - Schematic
 Figure 011

R 1EFF : 001-049, 051-099, 101-105, 1 33-51-00Page 92 1 1 Aug 01/05 1 1 1CES 1


 Lavatory Auxiliary Lights - Schematic
 Figure 011A

R 1EFF : 106-149, 159-199, 210-299, 401-499, 1 33-51-00Page 93 1 1 Aug 01/05 1 1 1CES 1


 Lavatory Auxiliary Lights - Schematic
 Figure 011B

R 1EFF : 151-158, 201-209, 1 33-51-00Page 94 1 1 Aug 01/05 1 1 1CES 1


 -three power supply units for the marking system of the floor-proximity emergency escape-path,
 -eight 6VDC wall-mounted exit-marking signs,
 -6VDC light moduls for the floor-proximity emergency-escape path-marking lights,
 -three 28VDC auxiliary lights, one installed in each lavatory.
 **ON A/C 106-149, 229-299,
 (Ref. Fig. 009A, 011A)
 A. Emergency Lighting System
 The emergency lighting system of the cabin consists of:
 -
four emergency power-supply units,

 -
four 6VDC overwing emergency lights, installed in the wing fairings,


 -a number of 6VDC escape slide lights as parts of the escape slides,
 -twelve 6VDC cabin emergency lights,
 -
four 6VDC escape hatch-handle lights,

 -
four 6VDC exit location signs,


 -six 6VDC exit marking signs,
 -eight 6VDC wall-mounted exit-marking signs,
 -photoluminescent strips in the aisle for the marking system of the floor-proximity emergency escape-path,
 -three 28VDC auxiliary lights, one installed in each lavatory.
 **ON A/C 151-158,
 (Ref. Fig. 009B, 010B, 011B)
 A. Emergency Lighting System
 The emergency lighting system of the cabin consists of:
 -
four emergency power-supply units,

 -
four 6VDC overwing emergency lights, installed in the wing fairings,


 -eleven 6VDC cabin emergency lights,
 -two 6VDC escape hatch-handle lights,
 -four 6VDC exit location signs,
 -six 6VDC exit marking signs,
 -three power supply units for the marking system of the floor-proximity emergency escape-path,
 -twenty-three 115VAC luminescent light strips for the floor-proximity emergency-escape path-marking lights,
 -six 115VAC wall-mounted exit-marking signs,
 -three 28VDC auxiliary lights, one installed in each lavatory.
R 1EFF : 051-099, 106-149, 151-158, 229-299, 1 33-51-00Page 95 1 1 Aug 01/05 1 1 1CES 1 **ON A/C 159-199,


 (Ref. Fig. 009C, 011A)
 A. Emergency Lighting System
 The emergency lighting system of the cabin consists of:
 -
four emergency power-supply units,

 -
four 6VDC overwing emergency lights, installed in the wing fairings,


 -eleven 6VDC cabin emergency lights,
 -two 6VDC escape hatch-handle lights,
 -four 6VDC exit location signs,
 -six 6VDC exit marking signs,
 -twenty-three 115VAC luminescent light strips for the floor-proximity emergency-escape path-marking lights,
 -six 115VAC wall-mounted exit-marking signs,
 -three 28VDC auxiliary lights, one installed in each lavatory.
 **ON A/C 210-210,
 (Ref. Fig. 009D, 011A)
 A. Emergency Lighting System
 The emergency lighting system of the cabin consists of:

 -
four emergency power-supply units,

 -
four 6VDC overwing emergency lights, installed in the wing fairings,


 -twelve 6VDC cabin emergency lights,
 -
four 6VDC escape hatch-handle lights,

 -
four 6VDC exit location signs,


 -six 6VDC exit marking signs,
 -twenty-six 115VAC luminescent light strips for the floor-proximity emergency-escape path-marking lights,
 -eight 115VAC wall-mounted exit-marking signs,
 -three 28VDC auxiliary lights, one installed in each lavatory.
R 1EFF : 159-199, 210-210, 1 33-51-00Page 96 1 1 Aug 01/05 1 1 1CES 1 **ON A/C 211-228,


 (Ref. Fig. 009D, 011A)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光2(85)