 (1) Do this test when the SYSTEM TEST through the MCDU is not available.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the emergency power-supply  On the emergency power-supply unit:
 unit:
 - push the TEST membrane switch  - the green SYSTEM OK LED comes on for
 for approximately 2 s.  approximately 30 s if all test loops
 are completed without malfunction. 

R 1EFF : 004-049, 053-099, 101-149, 151-199, 1 33-51-00Page 530 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL


 5. Close-up
________

R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 Subtask 33-51-00-410-053-A
 A. Close Access
 (1)
 Install the ceiling panel: FOR 10WL install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-400-001).

 (2)
 Install the lower sidewall panel: FOR 11WL install 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-400-001), FOR 12WL install 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-400-001).

 (3)
 Engage the emergency oxygen container: FOR 13WL lift and engage the emergency oxygen container 33WR between the AFT passenger/crew doors (Ref. TASK 35-21-41-400-001).

 (4)
 Remove the stepladder(s).


 **ON A/C 301-399,
 Subtask 33-51-00-410-053-B
 A. Close Access
 (1)
 Install the ceiling panel: FOR 10WL install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-400-001), FOR 11WL install 251KC between the rear emergency exit doors (Ref. TASK 25-23-41-400-001), FOR 12WL

 install 251KC between the rear emergency exit doors (Ref. TASK 25-23-41-400-001), FOR 14WL install 231JC between the forward emergency exit doors (Ref. TASK 25-23-41-400-001), FOR 15WL install 231JC between the forward emergency exit doors (Ref. TASK 25-23-41-400-001),

 (2)
 Engage the emergency oxygen container: FOR 13WL lift and engage the emergency oxygen container 33WR between the AFT passenger/crew doors (Ref. TASK 35-21-41-400-001).

 (3)
 Remove the stepladder(s).

 


 **ON A/C ALL
 Subtask 33-51-00-862-055
 B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
 1EFF : ALL 1 33-51-00Page 532 1 1 Aug 01/05R 1 1 1CES 1


 TASK 33-51-00-710-007
 Operational Test of the Emergency Lighting in the Cabin by 'LIGHT EMER' Pushbutton Switch
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
 3. Job Set-up
__________ Subtask 33-51-00-861-059
 A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). Subtask 33-51-00-865-058
 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU LIGHTING/EMER LT/CABIN 2WL H06 49VU LIGHTING/EMER LT/CABIN 1WL H05 122VU LIGHTING/CABIN/EMER/LT 3WL V07
 1EFF : ALL 1 33-51-00Page 533 1 1 Aug 01/05R 1 1 1CES 1


 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 Subtask 33-51-00-860-061
 C. Preparation for Test
 (1)
 On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.

 (2)
 On the overhead panel 25VU, make sure that the NO SMOKING switch 190RH is in the OFF position.

 (3)
 On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT EMER pushbutton switch and its integral light are off.

 

R **ON A/C 106-149, 301-399, 401-499,
 Subtask 33-51-00-860-061-A
 C. Preparation for Test
 (1)
 On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.

 (2)
 On the overhead panel 25VU, make sure that the NO SMOKING switch 190RH is in the OFF position.

 (3)
 On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER pushbutton switch and its integral light are off.
 