R 1EFF : 004-049, 053-099, 101-149, 151-199, 1 33-51-00Page 530 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
5. Close-up
________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 33-51-00-410-053-A
A. Close Access
(1)
Install the ceiling panel: FOR 10WL install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-400-001).
(2)
Install the lower sidewall panel: FOR 11WL install 241KW at the left emergency exit(s) (Ref. TASK 25-23-44-400-001), FOR 12WL install 242KW at the right emergency exit(s) (Ref. TASK 25-23-44-400-001).
(3)
Engage the emergency oxygen container: FOR 13WL lift and engage the emergency oxygen container 33WR between the AFT passenger/crew doors (Ref. TASK 35-21-41-400-001).
(4)
Remove the stepladder(s).
**ON A/C 301-399,
Subtask 33-51-00-410-053-B
A. Close Access
(1)
Install the ceiling panel: FOR 10WL install 221BC at the left FWD passenger/crew door (Ref. TASK 25-23-42-400-001), FOR 11WL install 251KC between the rear emergency exit doors (Ref. TASK 25-23-41-400-001), FOR 12WL
install 251KC between the rear emergency exit doors (Ref. TASK 25-23-41-400-001), FOR 14WL install 231JC between the forward emergency exit doors (Ref. TASK 25-23-41-400-001), FOR 15WL install 231JC between the forward emergency exit doors (Ref. TASK 25-23-41-400-001),
(2)
Engage the emergency oxygen container: FOR 13WL lift and engage the emergency oxygen container 33WR between the AFT passenger/crew doors (Ref. TASK 35-21-41-400-001).
(3)
Remove the stepladder(s).
**ON A/C ALL
Subtask 33-51-00-862-055
B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
1EFF : ALL 1 33-51-00Page 532 1 1 Aug 01/05R 1 1 1CES 1
TASK 33-51-00-710-007
Operational Test of the Emergency Lighting in the Cabin by 'LIGHT EMER' Pushbutton Switch
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
3. Job Set-up
__________ Subtask 33-51-00-861-059
A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). Subtask 33-51-00-865-058
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU LIGHTING/EMER LT/CABIN 2WL H06 49VU LIGHTING/EMER LT/CABIN 1WL H05 122VU LIGHTING/CABIN/EMER/LT 3WL V07
1EFF : ALL 1 33-51-00Page 533 1 1 Aug 01/05R 1 1 1CES 1
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 33-51-00-860-061
C. Preparation for Test
(1)
On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.
(2)
On the overhead panel 25VU, make sure that the NO SMOKING switch 190RH is in the OFF position.
(3)
On the Forward Attendant Panel (FAP) 120RH, make sure that the LIGHT EMER pushbutton switch and its integral light are off.
R **ON A/C 106-149, 301-399, 401-499,
Subtask 33-51-00-860-061-A
C. Preparation for Test
(1)
On the overhead panel 25VU, make sure that the EMER EXIT LT switch 4WL is in the OFF position.
(2)
On the overhead panel 25VU, make sure that the NO SMOKING switch 190RH is in the OFF position.
(3)
On the Flight Attendant Panel (FAP) 120RH, make sure that the EMER pushbutton switch and its integral light are off.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光2(118)