for the right wing bond the outboard bolt (3).
(4)
Remove the blanking caps from the disconnected electrical connectors.
(5)
Connect the electrical connectors (1) to the power supply unit.
Subtask 33-48-38-865-052
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 10LV.
Subtask 33-48-38-710-050
D. Test
WARNING : DO NOT LOOK DIRECTLY AT THE LIGHT FLASH DURING THE TEST.
_______ SUPPLY A COVER, OR SHIELD, TO GIVE PROTECTION FROM THE LIGHT FLASH TO PERSONS IN THE TEST AREA.
(1) Do an operational test of the strobe light (Ref. TASK 33-48-00-710-002)
Subtask 33-48-38-865-053
E. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU LIGHTING/WING/STROBE 10LV V05
5. Close-up
________ Subtask 33-48-38-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the applicable access panel:
-
FOR 15LV
install 534AB
-
FOR 14LV
install 634AB.
Subtask 33-48-38-865-054
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 10LV.
Subtask 33-48-38-942-052
C. Removal of Equipment
(1)
Remove the safety barriers.
(2)
Remove the warning notice(s).
(3)
Remove the access platform(s).
(4)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
POWER SUPPLY UNIT - TAIL CONE STROBE LIGHT (18LV) - REMOVAL/INSTALLATION
________________________________________________________________________ TASK 33-48-39-000-001 Removal of the Power Supply Unit (18LV) of the Tail Cone Strobe-Light
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
No specific access platform 3.5 m (11 ft. 6 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 33-48-39-991-001 Fig. 401
3. Job Set-up
__________ Subtask 33-48-39-861-050
A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). Subtask 33-48-39-865-053
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU LIGHTING/WING/STROBE 10LV V05
Subtask 33-48-39-010-050
C. Get Access
(1)
Put the access platform in position below the access door 314AR at Zone 310.
(2)
Open the access door 314AR.
4. Procedure
_________
(Ref. Fig. 401/TASK 33-48-39-991-001) Subtask 33-48-39-020-050
A. Removal of the Power Supply Unit (18LV)
(1)
Remove and discard the lockwires from the electrical connectors (4) and (5).
(2)
Disconnect the electrical connectors (4) and (5).
(3)
Put blanking caps on the disconnected electrical connectors.
(4)
Remove the screws (2) and the washers (3).
(5)
Remove the power supply unit (1).
Power Supply Unit
Figure 401/TASK 33-48-39-991-001
1EFF : ALL 1 33-48-39 Page 403
1 1 Feb 01/98
1 1
1CES 1
TASK 33-48-39-400-001
Installation of the Power Supply Unit (18LV) of the Tail Cone Strobe-Light
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光2(65)