(2)
Install the access panel:
FOR 110WL1
221BC (Ref. TASK 25-23-42-400-001),
FOR 110WL2
241GX (Ref. TASK 25-23-44-400-001),
FOR 110WL3
262VW (Ref. TASK 25-23-45-400-005).
(3)
Install the curtain rail: FOR 110WL3 install the AFT curtain rail (Ref. TASK 25-26-41-400-003).
(4)
Remove the stepladder.
(5)
Remove the ground support and maintenance equipment, the special and standard tools and all other items.
R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
TASK 33-51-39-920-001
Scheduled Capacity Check of the Battery installed in the Power Supply Unit for the Floor-Proximity Emergency-Escape Path-Marking Light
1.
Reason for the Job
__________________
Refer to the MPD TASK: 335100-04
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
33-51-39-000-001 Removal of the Power Supply Unit for the Floor-Proximity Emergency-Escape Path-Marking Light 33-51-39-400-001 Installation of the Power Supply Unit for the Floor-Proximity Emergency-Escape Path-Marking Light R CMM 256003 CMM 335193
3. Job Set-up
__________
Subtask 33-51-39-860-052
A. There is no special job set-up for this task.
4. Procedure
_________
Subtask 33-51-39-020-051
A. Remove the power supply unit of the floor-proximity emergency-escape path-marker (Ref. TASK 33-51-39-000-001).
R **ON A/C 001-049, 101-105, 151-158, 201-209,
Subtask 33-51-39-720-050
B. Check the capacity of the emergency battery (Ref. CMM 335193).
R **ON A/C 051-099,
R R R Subtask 33-51-39-720-050-A B. Check the capacity of the emergency battery (Ref. CMM 256003). **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
Subtask 33-51-39-420-051 C. Install the power supply unit (Ref. TASK 33-51-39-400-001).