634.
(2)
Remove the applicable glazing panel (3) (Ref. TASK 57-37-12-000-001).
Strobe Light
Figure 401/TASK 33-48-14-991-001
1EFF : ALL 1 33-48-14 Page 403
1 1 Feb 01/98
1 1
1CES 1
4. Procedure
_________
(Ref. Fig. 401/TASK 33-48-14-991-001) Subtask 33-48-14-020-050
A. Removal of the Strobe Light WARNING : DO NOT DISCONNECT THE ELECTRICAL CONNECTIONS FOR AT LEAST 2
_______ MINUTES AFTER YOU DE-ENERGIZE THE ELECTRICAL CIRCUITS.
(1)
Remove the bolts (4) and the washers (5).
(2)
Remove the strobe light sufficiently to get access to the electrical connector (1).
(3)
Disconnect the electrical connector (1).
(4)
Remove the strobe light (2).
(5)
Put blanking caps on the disconnected electrical connectors.
TASK 33-48-14-400-001
Installation of the Strobe Light
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______ START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______ GEAR.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific safety barriers No specific soap solution No specific warning notice No specific access platform 4.35 m (14 ft. 3 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-004 USA MIL-T-81533 1.1.1TRICHLOROETHANE (METHYL CHLOROFORM) (Ref. 20-31-00)
Material No. 15-008 AIB TN 10138 TYPE II GRADE 2 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819 LINT-FREE COTTON CLOTH (Ref. 20-31-00) C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
20-28-00-912-004 Bonding with Conductive Bolts and Screws and Bonding Straps in the Fuselage and in the Wings (this does not include the tanks)
33-48-00-710-001 Operational Test of the Anti-Collision/Strobe Lighting 33-48-00-710-002 Operational Test of the Anti-Collision/Strobe
Lighting 57-37-12-400-001 Installation of the Navigation Light Glazing Panel 33-48-14-991-001 Fig. 401
3. Job Set-up
__________
Subtask 33-48-14-941-053
A. Safety Precautions
(1)
Make sure that the safety barriers are in position.
(2)
Make sure that the warning notice is in position on panel 25VU to tell persons not to operate the navigation lights or the strobe lights.
Subtask 33-48-14-860-052
B. Aircraft Maintenance Configuration
(1) Make sure that the access platform is in position below the applicable zone 534, 634.
Subtask 33-48-14-865-051
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU LIGHTING/WING/STROBE 10LV V05
4. Procedure
_________
(Ref. Fig. 401/TASK 33-48-14-991-001) Subtask 33-48-14-420-052
A. Preparation for Installation
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光2(57)