R  **ON A/C 106-149, 229-299, 303-399,
 Subtask 33-51-21-910-050-A
 A. Preparation for Installation
 WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
 (1) Remove the sealant (2) with a nonmetallic scraper.
 (2) Clean the component interface and/or the adjacent area on the floor panels with CLEANING AGENTS (Material No. 11-003).
 (3) Do an inspection of the component interface and/or the adjacent area.
 Subtask 33-51-21-420-050-A
 B. Installation of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
 (1) Cut the photoluminescent strip (1) to length.
 (2) Remove the protective foil from the photoluminescent strip (1). 

R 1EFF : 106-149, 229-299, 303-399, 401-499, 1 33-51-21Page 413 1 1 Aug 01/05 1 1 1CES 1


 (3) Align the self-adhesive photoluminescent strip (1) and install it with a soft cotton cloth.
 NOTE : Make sure that the end of the photoluminescent strip (1) have____ a distance of 2.0 mm (0.0787 in.) from the next photoluminescent strip.
 NOTE : Make sure that you do the installation with light hand____ pressure. Do this from one end of the photoluminescent strip (1) to the other and make sure that it fits correctly.
 (4) Apply SEALANTS (Material No. 09-036) (2) between the photoluminescent strip (1) and the non-textile floor-covering. 
R  **ON A/C 401-499, 
R  Subtask 33-51-21-910-050 
R  A. Preparation for Installation 
R R R R R R R R R  WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED. 
R  (1) Remove the sealant (2) with a nonmetallic scraper. 
R R  (2) Clean the component interface and/or the adjacent area on the floor panels with CLEANING AGENTS (Material No. 11-003). 
R R  (3) Clean the component interface and/or the adjacent area on the convertible seat with CLEANING AGENTS (Material No. 11-010). 
R  (4) Do an inspection of the component interface and/or the adjacent area. 

R 1EFF : 106-149, 229-299, 303-399, 401-499, 1 33-51-21Page 414 1 1 Aug 01/05 1 1 1CES 1


R Subtask 33-51-21-420-050

R  B. Installation of the Photoluminescent Strip of the Floor-Proximity 
R  Emergency-Escape Path-Marking 
R  (1) Cut the photoluminescent strip (1) to length. 
R  (2) Remove the protective foil from the photoluminescent strip (1) and 
R  (5). 
R  (3) Align the self-adhesive photoluminescent strip (1) and (5) and 
R  install it with a soft cotton cloth. 
R  NOTE : Make sure that the end(s) of the photoluminescent strip (1)____ 
R  has (have) a distance of 2.0 mm (0.0787 in.) from the opposite 
R  end(s) of the next photoluminescent strip(s) (1). 
R  NOTE : Make sure that you do the installation with a light pressure____ 
R  of your hand; do this step from one end of the self-adhesive 
R  photoluminescent strip (1) and (5) towards the other end and 
R  that it fits correctly. 
R  (4) Apply SEALANTS (Material No. 09-036) (2) between the photoluminescent 
R  strip (1) and the non-textile floor-covering. 
R  **ON A/C 106-149, 229-299, 303-399, 401-499,
 5. Close-up________
 Subtask 33-51-21-860-052
 A. De-energize the ground service network
 (Ref. TASK 24-42-00-862-001)


 TASK 33-51-21-920-002


 Discard Photoluminescent Floor Path Marking System
 1.
 Reason for the Job

__________________
 Refer to the MPD TASK: 335100-07


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
33-51-21-000-001  Removal of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking 33-51-21-400-001 Installation of the Photoluminescent Strip of the Floor-Proximity Emergency-Escape Path-Marking
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光2(152)