R 1EFF : 001-049, 101-105, 151-199, 201-228, 1 33-51-12Page 409 1301-302, 1May 01/05 1 1 1CES 1
**ON A/C 151-199,
(Ref. Fig. 401A/TASK 33-51-12-991-001-A)
R **ON A/C 211-228,
(Ref. Fig. 401B/TASK 33-51-12-991-001-B)
R **ON A/C 301-302,
(Ref. Fig. 401C/TASK 33-51-12-991-001-D)
R **ON A/C 001-049, 101-105, 151-199, 201-228, 301-302,
Subtask 33-51-12-910-050
A. Preparation for Installation
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interface and/or the adjacent area with a lint free cloth.
(3) Do an inspection of the component interface and/or the adjacent area.
R **ON A/C 001-049, 101-105, 151-199, 201-210,
Subtask 33-51-12-420-056
B. Installation of the Floor-Proximity Emergency-Escape Path-Marker
(1) Make sure that the electrical connectors are clean and in the correct condition. Make sure that the work area is clean and clear of tool(s) and other items. FOR 120WL, 121WL
(2) Connect the electrical connector of the flexible light strip (3) to the straight cable connector (2).
R 1EFF : 001-049, 101-105, 151-199, 201-228, 1 33-51-12Page 410 1301-302, 1May 01/05 1 1 1CES 1
(3) Put the flexible light strip (3) in position in the track housing (4).
(4) Install the top lamp housing (1). R **ON A/C 211-228, 301-302,
Subtask 33-51-12-420-056-A
B. Installation of the Floor-Proximity Emergency-Escape Path-Marker
(1)
Make sure that the electrical connectors are clean and in the correct condition. Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Connect the electrical connector of the flexible light strip (3) to the straight cable connector (2).
(3)
Put the flexible light strip (3) in position in the track housing (4).
(4) Install the top lamp housing (1). R **ON A/C 001-049, 101-105, 151-199, 201-228, 301-302,
Subtask 33-51-12-710-051
C. Do the operational test of the cabin emergency lighting (Ref. TASK 33-51-00-710-009).
5. Close-up
________
Subtask 33-51-12-860-053
A. Put the aircraft back to the serviceable condition.
(1) Make sure that the work area is clean and clear of tool(s) and other items.
R 1EFF : 001-049, 101-105, 151-199, 201-228, 1 33-51-12Page 411 1301-302, 1May 01/05 1 1 1CES 1
R **ON A/C 051-099,
R TASK 33-51-12-000-002
R Removal of the Marking Light of the Floor-Proximity Emergency-Escape Path
R (BRUCE)
R WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE_______
R YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
R NOTE : The procedure is the same for all the floor-proximity emergency-escape____
R path-markers in Zone 200.
R 1. Reason for the Job__________________
R Self Explanatory
R 2. Job Set-up Information______________________
R A. Fixtures, Tools, Test and Support Equipment
R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------
R No specific circuit breaker(s) safety clip(s)
R B. Referenced Information
R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R 33-51-12-991-003 Fig. 402
R 3. Job Set-up__________
R Subtask 33-51-12-865-054
R A. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 49VU LIGHTING/EMER LT/CABIN 2WL H06
中国航空网 www.aero.cn