__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking cap
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
33-43-11-991-001 Fig. 401 3. Job Set-up
__________ Subtask 33-43-11-865-050
A. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 3LC1
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06 FOR 3LC2 122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05
4. Procedure
_________
(Ref. Fig. 401/TASK 33-43-11-991-001) Subtask 33-43-11-020-050
A. Removal of the Light
(1)
Disconnect the electrical connector (5) from its support.
(2)
Put the blanking cap on the disconnected electrical connector (5) and on its support.
(3)
Remove the two nuts (1) and the washers (2). During this operation, hold the optical unit.
(4)
Remove the optical unit (4).
Runway Turnoff Light
Figure 401/TASK 33-43-11-991-001
1EFF : ALL 1 33-43-11 Page 403
1 1 Feb 01/98
1 1
1CES 1
TASK 33-43-11-400-001
Installation of the Runway Turnoff Light (3LC1, 3LC2)
WARNING : WEAR GLASSES AND PROTECTIVE CLOTHING WHEN YOU WORK ON THE LIGHT.
_______
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
Material No. 05-002 USA MIL-P-8116 PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
33-43-00-710-001 Operational Test of the Runway Turnoff Lights R 33-43-11-730-001 Adjustment of the Runway Turnoff Light (3LC1, 3LC2)
3. Job Set-up
__________
Subtask 33-43-11-865-051
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 3LC1
122VU LIGHTING/EXT LT/RWY TURN OFF/L 1LC1 W06 FOR 3LC2 122VU LIGHTING/EXT LT/RWY TURN OFF/R 1LC2 W05
4. Procedure
_________
R **ON A/C 001-049, 052-099, 101-149, 151-199, 201-299, 301-399, 401-499,
Subtask 33-43-11-420-050-A
A. Installation of the Light
(1)
Clean the component interface and/or the adjacent area.
(2)
Do an inspection of the component interface and/or the adjacent area.
(3)
Make sure that the filament of the lamp and the lens are in the correct condition.
(4)
Remove the blanking cap from the electrical connector (5) and from the support.
(5)
Make sure that the electrical connector (5) is in the correct condition.
(6)
Connect the electrical connector (5) to its support.
(7)
Put the optical unit (4) in position on its support (3). Hold it in this position.
(8)
Apply SPECIAL MATERIALS (Material No. 05-002) to the screws (1).
(9)
Install the optical unit (4) with the two screws (1) and the washers (2).
**ON A/C 051-051,
Subtask 33-43-11-420-050
A. Installation of the Light
(1)
Clean the component interface and/or the adjacent area.
(2)
Do an inspection of the component interface and/or the adjacent area.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LIGHTS 灯光2(14)