• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 23:24来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

A
737-300/400/500MAINTENANCE MANUAL
 AIR DATA COMPUTER - REMOVAL/INSTALLATION
________________________________________
 1.  General
_______
 A.  This procedure has two tasks. The first task is to remove the air data computer (ADC). The second task is to install the ADC. The installation task includes a test of the installation of the ADC.
 B.  The air data computers are installed on the E1-1 electrical shelf.
 C.  The circuit breakers for the ADC-1 (M196) are on the P18 load control center. The circuit breakers for the ADC-2 (M368) are on the P6 load control center.
 D.  This procedure is applicable to all air data computers.
 TASK 34-12-11-024-001
 2.  Air Data Computer Removal
_________________________
 A.  References
 (1)  AMM 20-10-07/201, Electrical/Electronic Black Box
 B.  Access
 (1)  Location Zone
 25 Electronic Compartment

 C.  Procedure
 S 864-002
 (1)  Open the applicable circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  
P18 Load Control Center
 1) A8, COMPUTER-1 AC
 2) A9, COMPUTER-1 (26V AC)


 (b)  
P6 Load Control Center
 1) B6, COMPUTER-2 26V AC
 2) B7, COMPUTER-2 AC

 

 S 034-024
 CAUTION: DO NOT DISCONNECT THE PITOT-STATIC SYSTEM HOSES WHEN THE SYSTEM
_______ IS NOT AT AMBIENT PRESSURE. THIS CAN CAUSE DAMAGE TO THE AIR DATA COMPUTER.
 (2)  Disconnect the pitot-static system hoses from the front panel of the air data computer.
 S 024-025
 CAUTION: DO NOT TOUCH THE CONNECTOR PINS OR OTHER CONDUCTORS ON THE AIR
_______ DATA COMPUTER. IF YOU TOUCH THESE CONDUCTORS, ELECTROSTATIC DISCHARGE FROM YOUR BODY CAN CAUSE DAMAGE TO THE AIR DATA COMPUTER.
 (3)  
Remove the air data computer (AMM 20-10-07/201).

 (4)  
Install dust caps on the electrical connections.


 S 494-005
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-12-11

 ALL  ú ú 01 Page 401 ú Jul 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 TASK 34-12-11-424-006
 3. Air Data Computer Installation
______________________________
 A. General
 (1)  
You do not have to do a leak test when you connect a quick-disconnect fitting. A visual examination of the quick-disconnect for a complete seal is necessary. You must do a leak test when you cannot make sure that the quick-disconnect has a complete seal.

 (2)  
You must do a leak test of the pitot and static systems if you installed quick-disconnects on the air data computer.


 B. References
 (1)  
AMM 20-10-07/201, Electrical/Electronic Black Box

 (2)  
AMM 24-22-00/201, Manual Control


 C. Access
 (1)  Location Zone
 25 Electronic Compartment

 D. Procedure
 S 864-007
 (1)  Make sure that the applicable circuit breakers are open with the DO-NOT-CLOSE tags attached.
 (a)  
P18 Load Control Center
 1) A8, COMPUTER-1 AC
 2) A9, COMPUTER-1 (26V AC)


 (b)  
P6 Load Control Center
 1) B6, COMPUTER-2 26V AC
 2) B7, COMPUTER-2 AC

 

 S 094-023
 CAUTION: DO NOT TOUCH THE CONNECTOR PINS OR OTHER CONDUCTORS ON THE AIR
_______ DATA COMPUTER. IF YOU TOUCH THESE CONDUCTORS, ELECTROSTATIC DISCHARGE FROM YOUR BODY CAN CAUSE DAMAGE TO THE AIR DATA COMPUTER.
 (2)  
Remove the dust caps from the electrical connections.

 (3)  
Install the air data computer (AMM 20-10-07/201).


 S 424-009
 S 434-022
 CAUTION: DO NOT CONNECT THE PITOT-STATIC SYSTEM HOSES WHEN THE SYSTEM IS
_______ NOT AT AMBIENT PRESSURE. THIS CAN CAUSE DAMAGE TO THE AIR DATA COMPUTER.
 (4)  Connect the pitot-static system hoses to the front panel of the air data computer.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 导航 NAVIGATION 1(88)