A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
(2)
In the cockpit, on the overhead ELEC panel 35VU, make sure that the GEN 1 and GEN 2 pushbutton switches are in ON position (FAULT legend ON).
(3)
On the MCDU, get the SYSTEM REPORT/TEST page of the ELEC system (Ref. TASK 31-32-00-860-004).
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 24-41-00Page 501 1201-228, 301-302, 401-499, 1Aug 01/05 1 1 1CES 1 Subtask 24-41-00-865-051
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU ELEC/GCU/2 2XU2 T27 122VU ELEC/GCU/1 2XU1 T26 122VU ELEC/APU/GCU 6XS Y25 122VU ELEC/GPCU 7XG Y24 123VU GND/PWR/PROT 2XG AB07
4. Procedure
_________
Subtask 24-41-00-710-062
A. Test of the GPCU from the Centralized Fault Display System (CFDS)
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the MCDU, on the SYSTEM REPORT/TEST page of the ELEC system:
-push the line key adjacent to the AC GEN indication
2. On the AC GEN page:
-push the line key adjacent to the TEST indication
3. On the ELEC panel 35VU:
-release the GEN 1 and GEN 2 pushbutton switches
-push the GEN 1 and GEN 2
pushbutton switches
4. On the MCDU:
-push the line key adjacent to the RETURN indication until the AC GEN page comes into view.
On the MCDU:
-
the AC GEN page comes into view.
On the MCDU, on the AC GEN page:
-
the TEST WAIT message comes into view(after a few seconds),
-then the TEST OK message comes into view (after a few seconds).
On the ELEC panel 35VU:
-
the OFF legend of the GEN 1 and GEN 2pushbutton switches comes on.
-
the FAULT legend of the GEN 1 and GEN2 pushbutton switches comes on.
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 24-41-00Page 502 1201-228, 301-302, 1May 01/05 1 1 1CES 1 Subtask 24-41-00-710-063
B. Check of the class 3 faults of the GPCU from the CFDS
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the MCDU, on the SYSTEM On the MCDU: REPORT/TEST page of the ELEC - the AC GEN page comes into view. system:
-push the line key adjacent to
the AC GEN indication
2. On the AC GEN page: On the AC GEN page:
-push the line key adjacent to - the NO FAULT message comes into view. the CLASS 3 FAULTS indication
5. Close-up
________
Subtask 24-41-00-860-056
A. Put the aircraft back to its initial configuration.
(1)
On the MCDU, push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.
(2)
De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002).
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 24-41-00Page 503 1201-228, 301-302, 1May 01/05 1 1 1CES 1R **ON A/C 401-499,
R TASK 24-41-00-740-002-A R Operational Check of GAPCU via CFDS R 1. Reason for the Job
__________________ R Refer to the MPD TASK: 242000-01 R 2. Job Set-up Information
______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------