R R Location of Conduit Fittings Figure 609/TASK 24-92-00-991-013-A14 (SHEET 1)
1EFF : 1 1 1CES ALL 1 111 24-92-00 Page 628 May 01/04
R R Location of Conduit Fittings Figure 609/TASK 24-92-00-991-013-A24 (SHEET 2)
1EFF : 1 1 1CES ALL 1 111 24-92-00 Page 629 May 01/04
R R Location of Conduit Fittings Figure 609/TASK 24-92-00-991-013-A34 (SHEET 3)
1EFF : 1 1 1CES ALL 1 111 24-92-00 Page 630 May 01/04
R R Location of Conduit Fittings Figure 609/TASK 24-92-00-991-013-A44 (SHEET 4)
1EFF : 1 1 1CES ALL 1 111 24-92-00 Page 631 May 01/04
(1) At each fitting, use the procedure that follows to protect against corrosion:
(a)
Use CLEANING AGENTS (Material No. 11-004) and a lint-free cloth to remove any contamination from the fitting.
(b)
Remove any flakes or blisters, make sure that the you do not damage the base metal while you do this task.
NOTE : A dental or a seal tools are recommended for the removal
____
of flakes and blisters.
(c) Use a brush or an airless spray to apply a continuous coat of STORAGE PRESERVATION (Material No. 15-008) with a thickness of
0.030 mm (0.001 in.), to cover all the fitting.
5. Close-up
________ Subtask 24-92-00-410-056
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
For the left wing.
(a) Install the access panel: 575BB, 575CB, 575DB, 575EB, 575FB, 575GB, 575HB, 575KB, 575LB, 575MB.
(3)
For the right wing.
(a) Install the access panel: 675BB, 675CB, 675DB, 675EB, 675FB, 675GB, 675HB, 675KB, 675LB, 675MB.
Subtask 24-92-00-860-062
B. Put the aircraft back to its initial configuration.
(1)
Disconnect the aircraft from the ground (Ref. TASK 12-34-24-869-002).
(2)
Retract the spoilers (Ref. TASK 27-60-00-866-002).
(3)
Retract the flaps (Ref. TASK 27-50-00-866-009).
(4)
Remove the access platform(s).
R 1EFF : ALL 1 24-92-00Page 632 1 1 Feb 01/04 1 1 1CES 1 TASK 24-92-00-210-007
Inspection of the End Fittings of Electrical Conduits in the Air Conditioning Compartment
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______ GEAR.
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______ START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.
WARNING : MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND THE CAUTIONS INCLUDED IN
_______ THE REFERENCED PROCEDURES.
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS
_______ ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
1. Reason for the Job
__________________
Refer to the MPD TASK: 240000-11 Apply temporary protection to end fittings of electrical conduits in the air conditioning compartment.
R 1EFF : ALL 1 24-92-00Page 633 1 1 Feb 01/04 1 1 1CES 1
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific airless spray
No specific brush
No specific dental
No specific lint-free cloth
No specific seal tools
No specific adjustable access platform 2 m (6 ft. 7 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-004 USA MIL-T-81533
1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
(Ref. 20-31-00)
Material No. 15-008 AIB TN 10138 TYPE II GRADE 2 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00)
C. Referenced Information