4. Procedure_________
Subtask 24-56-00-440-050
A. Do the trouble-shooting of the galley supply system and do the applicable correct action (Ref. TSM TASK 24-56-00-810-801).
5. Close-up
________ Subtask 24-56-00-862-052
A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
GALLEY SUPPLY - ADJUSTMENT/TEST
_______________________________
TASK 24-56-00-710-001
Operational Test of the Galley Supply
WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
1. Reason for the Job__________________ Self Explanatory
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
3. Job Set-up
__________ Subtask 24-56-00-860-050
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
(2)
Make sure that the pushbutton switch GALLEY 2XA, on the overhead panel 35VU is in the OFF position (a white indication light shows OFF).
Subtask 24-56-00-865-052
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------R **ON A/C ALL
**ON A/C 001-049, 051-060, 101-102, 201-201,
122VU ELEC/GALLEY/CTL **ON A/C ALL 1XA S26
R 122VU ELEC/GALLEY/CNTOR **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499, 7MC S28
122VU ELEC/GALY & CAB/CTL **ON A/C ALL 1XA S26
123VU FWD GALLEY/FEEDER F 123VU AFT GALLEY/FEEDER E **ON A/C 301-399, 16MC 14MC AC10AF09
R 123VU FWD GALLEY/FEEDER C 123VU FWD GALLEY/FEEDER D 1MC 2MC AE03AE02
R **ON A/C 301-399, 401-499,
R R 123VU AFT GALLEY/FEEDER A **ON A/C 401-499, 3MC AF04
R R R 123VU AFT GALLEY/FEEDER B 123VU FWD GALLEY/FEEDER D 123VU FWD GALLEY/FEEDER C 12MC 2MC 1MC AD09 AD04 AF09
4. Procedure
_________
Subtask 24-56-00-710-050
A. Operational test of the Gally Supply
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the overhead panel 35VU: On the overhead panel 35VU:
-
push the GALLEY pushbutton - the white indicator light goes off. switch 2XA.
-
push and release the GALLEY - the white indicator light comes on. pushbutton switch 2XA again.