 Put warning notices in position on the access door 121AL to tell persons not to connect the external power connector to the aircraft EXT PWR receptacle.

 (3)
 In the cockpit, on the ELEC panel 35VU, make sure that these pushbutton switches are released:

 -BAT 1, BAT 2,
 -APU GEN,
 -GEN 1, GEN 2,
 -EXT PWR.

 (4)
 In the cockpit, put warning notices in position to tell the persons not to operate the pushbutton switches on these overhead panels:


 -21VU (EMER ELEC PWR section),
 -25VU (APU section)
 -35VU (ELEC).
 4. Procedure
_________ R **ON A/C 001-049, 051-062, 101-105, 151-152, 201-205,
 (Ref. Fig. 401/TASK 24-35-55-991-005)


 Contactors
 Figure 401/TASK 24-35-55-991-005

R 1EFF : 001-049, 051-062, 101-105, 151-152, 1 24-35-55Page 403 1201-205, 1May 01/05 1 1 1CES 1R **ON A/C 063-099, 106-149, 153-199, 206-299, 301-399, 401-499,

 

 (Ref. Fig. 401A/TASK 24-35-55-991-005-A)
 **ON A/C ALL

 Subtask 24-35-55-020-050
 A. Removal of the Contactor CAUTION : REMOVE THE CONTACTOR ONLY AND NOT THE BASE OR THE MODULE WHERE
_______
 THE WIRES ARE CONNECTED.

 (1)
 Disconnect the electrical connector (4).

 (2)
 Put a blanking caps on the disconnect electrical connector (4) and the electrical receptacle.

 (3)
 Loosen the captive screws (3). NOTE : Do not remove the captive screws (3) and the spring washers

____
 from the contactor (5).


 (4)
 Remove the contactor (5).

 


 Contactors
 Figure 401A/TASK 24-35-55-991-005-A

R 1EFF : 063-099, 106-149, 153-199, 206-299, 1 24-35-55Page 405 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 TASK 24-35-55-400-001
 Installation of the Contactor (1PC1, 1PC2)
 WARNING : MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT

_______
 ELECTRICAL CIRCUITS.
 THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS
 CONNECTED.

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notice
 No specific Torque Wrench : range 33.63 to 41.6 lbf.in

 (0.38 to 0.47 m.daN)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-32-00-710-001 Operational Test of the DC Generation Switching
 25-11-41-000-001 Removal of the Third Occupant Seat
 25-11-41-400-001 Installation of the Third Occupant Seat

 **ON A/C 001-049, 051-062, 101-105, 151-152, 201-205,
 24-35-55-991-005 Fig. 401 R **ON A/C 063-099, 106-149, 153-199, 206-299, 301-399, 401-499,
 24-35-55-991-005-A Fig. 401A **ON A/C ALL


 3. Job Set-up
__________
 Subtask 24-35-55-860-051
 A. Aircraft Maintenance Configuration
 (1)
 Make sure that the access platform is in position at the access door 121AL.

 (2)
 Make sure that the access door 121AL is open.

 (3)
 Make sure that the external power connector is not connected to the aircraft receptacle.

 (4)
 Make sure that, on the access door 121AL, there is a warning notice to tell persons not to connect the external power connector.

 (5)
 In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:

 -BAT 1, BAT 2,
 -APU GEN,
 -GEN 1, GEN 2,
 -EXT PWR.

 (6)
 Make sure that there is a warning notice in the cockpit to tell persons not to operate the pushbutton switches on these overhead panels:

 -21VU (EMER ELEC PWR),
 -35VU (ELEC).

 (7)
 In the cockpit, on the APU section of the overhead panel 25VU, make sure that a warning notice is in position to tell persons not to start the APU.

 (8)
 In the cockpit, make sure that the third occupant seat is removed (Ref. TASK 25-11-41-000-001).

 (9)
 In the cockpit, make sure that the front panel on the bottom right side of the panel 120VU is removed.
 