 TASK 24-56-00-040-001
 Deactivation of the Galley Supply System
 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 24-56-01 b)
 Galley Supply - Galley Supply System
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific  circuit breaker(s) safety clip(s)
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
 3. Job Set-up
__________ R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
 Subtask 24-56-00-860-052
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

 (2)
 Make sure that the pushbutton switch GALLEY 2XA on the overhead panel 35VU is in the OFF position (white indication light shows OFF).

 

 

R **ON A/C 106-149, 159-199, 210-299, 301-399, 401-499,
 Subtask 24-56-00-860-052-A
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

 (2)
 Make sure that the C/B 1XA on the 122VU is closed.

 (3)
 Make sure that the pushbutton switch GALLEY 2XA on the overhead panel 35VU is in the OFF position (white indication light shows OFF).

 (4)
 Make sure that the pushbutton switch ELEC/COMMERCIAL 22XN on the overhead panel 35VU is in the on position (white indication OFF is off).


 **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
 Subtask 24-56-00-865-050
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
122VU ELEC/GALLEY/CNTOR 7MC S28
 **ON A/C 001-049, 051-060, 101-102, 201-201,
 122VU ELEC/GALLEY/CTL 1XA S26 **ON A/C 061-099, 103-105, 151-158, 202-209,
 122VU ELEC/GALY & CAB/CTL 1XA S26 **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
 123VU FWD GALLEY/FEEDER F 16MC AC10 123VU AFT GALLEY/FEEDER E 14MC AF09


R  **ON A/C 106-149, 159-199, 210-299, 301-399, 401-499,
 Subtask 24-56-00-865-053
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU ELEC/GALLEY/CNTOR 7MC S28 123VU FWD GALLEY/FEEDER F 16MC AC10 123VU AFT GALLEY/FEEDER E 14MC AF09
 **ON A/C 301-399,
R  123VU FWD GALLEY/FEEDER C 123VU FWD GALLEY/FEEDER D  1MC 2MC  AE03AE02 
R  **ON A/C 301-399, 401-499, 
R  123VU AFT GALLEY/FEEDER A  3MC  AF04 
R  **ON A/C 401-499, 
R R R  123VU AFT GALLEY/FEEDER B 123VU FWD GALLEY/FEEDER D 123VU FWD GALLEY/FEEDER C  12MC 2MC 1MC  AD09 AD04 AF09
 **ON A/C ALL
 4. Procedure_________
 Subtask 24-56-00-040-050
 A. Make sure that the galley electrical panel(s) and galley equipment(s) does (do) not operate.

 

 5. Close-up
________ Subtask 24-56-00-862-050
 A. De-energize the aircraft electical circuits (Ref. TASK 24-41-00-862-002).
 1EFF : ALL 1 24-56-00Page 404 1 1 Aug 01/05R 1 1 1CES 1


 TASK 24-56-00-440-001 Reactivation of the Galley Supply System
 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 24-56-01 b)
 Galley Supply - Galley Supply System

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power TSM 24-56-00-810-801 Galley Supply Fault
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源2(128)