B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 3PC, 1XC, 2XC, 7XE, 4PE, 6XE
Subtask 24-25-55-710-050
C. Do an operational test of the AC essential generation switching (Ref. TASK 24-25-00-710-001).
5. Close-up
________
Subtask 24-25-55-410-050
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access door (14) on the panel 106VU.
(3)
Remove the warning notice(s).
(4)
Close the access door 812.
(5)
Remove the access platform(s).
1EFF : ALL 1 24-25-55Page 408 1 1 May 01/03R 1 1 1CES 1
GALLEY SUPPLY CONTROL - DESCRIPTION AND OPERATION
_________________________________________________
1. General
_______
The galley assembly is divided into several parts:
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
-Aft galley,
-Forward galley.
NOTE : For some more information (Ref. 24-56-00).
____
**ON A/C 301-399,
-Aft galley,
-Forward galley,
-Mid galley.
NOTE : For some more information (Ref. 24-56-00).
____ R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,
Furthermore, the galley supply control powers two AC and DC sheddable busbars.
**ON A/C ALL
2. Component Location
__________________
**ON A/C 001-049, 051-060, 101-102, 201-201,
(Ref. Fig. 001) R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,
(Ref. Fig. 001A)
Galley Supply Control - Component Location
Figure 001
R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 24-26-00Page 2 1 1 May 01/05 1 1 1CES 1
Galley Supply Control - Component Location
Figure 001A
R 1EFF : 061-099, 103-149, 151-199, 202-299, 1 24-26-00Page 3 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
-------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA | | | | DOOR | REF. -------------------------------------------------------------------------------2XA P/BSW-ELEC/GALLEY 35VU 210 831 24-26-00
3. System Description
__________________
**ON A/C 001-049, 051-060, 101-102, 201-201,
(Ref. Fig. 002)
**ON A/C 061-099, 103-105, 151-158, 202-209,
(Ref. Fig. 002A)
R **ON A/C 106-149, 159-199, 210-299, 401-499,
(Ref. Fig. 002B)
**ON A/C 301-399,
(Ref. Fig. 002C)
**ON A/C 001-049, 051-060, 101-102, 201-201,
The galley general supply is controlled from flight compartment overhead panel 35VU by means of GALLEY pushbutton switch (normal operation when the pushbutton is pressed in).
**ON A/C 061-099, 103-105, 151-158, 202-209,
The galley general supply is controlled from the cockpit ELEC panel 35VU by means of the GALY & CAB pushbutton switch (normal operation when the pushbutton is pressed in).
Galley Supply Control - Block Diagram
Figure 002
R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 24-26-00Page 5 1 1 May 01/05 1 1 1CES 1
Galley Supply Control - Block Diagram
Figure 002A
R 1EFF : 061-099, 103-105, 151-158, 202-209, 1 24-26-00Page 6 1 1 May 01/05 1 1 1CES 1
Galley Supply Control - Block Diagram
Figure 002B
R 1EFF : 106-149, 159-199, 210-299, 401-499, 1 24-26-00Page 7 1 1 Aug 01/05 1 1 1CES 1
R Galley Supply Control - Block Diagram
R Figure 002C
R 1EFF : 301-399, 1 24-26-00 Page 8
1 1 Nov 01/04
1 1
1CES 1
R **ON A/C 106-149, 159-199, 210-299, 301-399, 401-499,
If the OFF legend of COMMERCIAL pushbutton switch (commercial load shed) is off (pushbutton switch pressed in), galley general supply can be controlled from flight compartment overhead panel 35VU by means of GALLEY pushbutton switch (normal operation when the pushbutton is pressed in).
**ON A/C ALL
4. Operation/Control and Indicating
________________________________
**ON A/C 001-049, 051-060, 101-102, 201-201,
A. Galley Automatic Shedding
(Ref. Fig. 002) If only one generator is available, galley(s) (primary feeders controlled by the relay 6XA) is(are) automatically shedded. White GALLEY SHED indication appears on the ELEC page of the lower ECAM display unit (no light on GALLEY pushbutton switch).