R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 24-26-00Page 502 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4.
On the panel 122VU: - open the circuit breaker 7XA.
5.
On the ECAM control panel:
-push the STS key to get the STATUS page, INOP SYS section.
6.
On the panel 122VU:
-close the circuit breaker 7XA.
7.
On the ECAM control panel:
-push the ELEC key to get the ELEC system page.
5. Close-up
________
Subtask 24-26-00-860-051 In the forward and aft galleys:
-make sure that all the galley equipment operate.
On the lower ECAM display unit, on theELEC page:
-the white GALLEY SHED indication comes into view.
In the forward and aft galleys:
-make sure that only a part of the galley equipment operate.
On the lower ECAM display unit:
-
the MAIN GALLEY indication comes intoview.
On the lower ECAM display unit:
-
the GALLEY SHED indication goes outof view.
In the forward and aft galleys:
-make sure that all the galley equipment operate.
A. Put the aircraft back to its initial configuration.
(1)
De-energize the aircraft electrical circuits supplied from the external power (Ref. TASK 24-41-00-862-002) or from the APU (Ref. TASK 24-41-00-862-002).
(2)
Do the EIS stop procedure
(Ref. TASK 31-60-00-860-002).
R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 24-26-00Page 503 1 1 May 01/05 1 1 1CES 1R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,
TASK 24-26-00-710-002
Operational Test of the Manual and Automatic Galley and Bus Shedding
1. Reason for the Job
__________________
Refer to the MPD TASK: 242600-02
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the APU 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the APU
31-60-00-860-001 EIS Start Procedure
31-60-00-860-002 EIS Stop Procedure
ASM 24-56/01
3. Job Set-up
__________
Subtask 24-26-00-860-054
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits from the external power (Ref. TASK 24-41-00-861-002) or from the APU (Ref. TASK 24-41-00-861-002).
(2)
Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
(3)
In the cockpit, on the overhead ELEC panel 35VU, make sure that the GALY & CAB pushbutton switch is pushed (the OFF legend is off).