 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU ELEC/GALLEY/CTL 1XA S26 122VU ELEC/GALLEY/FAULT/LT CTL 8XA S25 122VU ELEC/GALLEY/GND/FLT/LOGIC 7XA S24
R
 4. Procedure
_________
 Subtask 24-26-00-710-050
 A. Operational Test of the Manual and Automatic Shedding of the Galleys
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ECAM control panel: - push the ELEC key to get the ELEC system page. On the lower ECAM display unit:- the ELEC page comes into view.
 2. On the panel 35VU: - release the GALLEY pushbutton switch.  On the panel 35VU:- the OFF legend of the GALLEYpushbutton switch comes on.
 On the lower ECAM display unit: - the white GALLEY SHED indication
 comes into view.
 In the forward and aft galleys: - make sure that no equipment operates.
 3. On the panel 35VU: - push the GALLEY pushbutton switch.  On the panel 35VU:- the OFF legend of the GALLEYpushbutton switch goes off.
 On the lower ECAM display unit: - the white GALLEY SHED indication goes out of view. 

R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 24-26-00Page 502 1 1 May 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4.
 On the panel 122VU: - open the circuit breaker 7XA.

5.
 On the ECAM control panel:

-push the STS key to get the STATUS page, INOP SYS section.

6.
 On the panel 122VU:

 -close the circuit breaker 7XA.

 7.
 On the ECAM control panel:


-push the ELEC key to get the ELEC system page.
5. Close-up
________
 Subtask 24-26-00-860-051 In the forward and aft galleys:
 -make sure that all the galley equipment operate.
On the lower ECAM display unit, on theELEC page:
 -the white GALLEY SHED indication comes into view.
 In the forward and aft galleys:
 -make sure that only a part of the galley equipment operate.
On the lower ECAM display unit:
-
the MAIN GALLEY indication comes intoview.

On the lower ECAM display unit:

-
the GALLEY SHED indication goes outof view.


 In the forward and aft galleys:
 -make sure that all the galley equipment operate.
 A. Put the aircraft back to its initial configuration.
 (1)
 De-energize the aircraft electrical circuits supplied from the external power (Ref. TASK 24-41-00-862-002) or from the APU (Ref. TASK 24-41-00-862-002).

 (2)
 Do the EIS stop procedure
 (Ref. TASK 31-60-00-860-002).

 

R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 24-26-00Page 503 1 1 May 01/05 1 1 1CES 1R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,

 

 TASK 24-26-00-710-002
 Operational Test of the Manual and Automatic Galley and Bus Shedding
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 242600-02
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the APU 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the APU
 31-60-00-860-001 EIS Start Procedure
 31-60-00-860-002 EIS Stop Procedure
 ASM 24-56/01

 3. Job Set-up
__________
 Subtask 24-26-00-860-054
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits from the external power (Ref. TASK 24-41-00-861-002) or from the APU (Ref. TASK 24-41-00-861-002).

 (2)
 Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).

 (3)
 In the cockpit, on the overhead ELEC panel 35VU, make sure that the GALY & CAB pushbutton switch is pushed (the OFF legend is off).


 