B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 24-37-21-991-001 Fig. 401
3. Job Set-up
__________ Subtask 24-37-21-860-050
A. Aircraft Maintenance Configuration
(1)
Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
(2)
Make sure that the access platform is in position at the avionics compartment door 822.
(3)
Make sure that the access door 822 is open.
(4)
Make sure that the access panel of the BATTERY power center 105VU is opened.
Subtask 24-37-21-865-051
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
R RR R -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 3PV1 105VU ELEC/BAT REF/BCL1 9PB1 F01 FOR 3PV2 105VU ELEC/BAT REF/BCL2 9PB2 F02
4. Procedure_________
(Ref. Fig. 401/TASK 24-37-21-991-001)
Subtask 24-37-21-420-050
A. Installation of the Voltmeter
CAUTION : REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU_______ CONNECT THE ELECTRICAL WIRES.
(1) Put the voltmeter (1) in position.
(2) Install the two screws (4) and tighten them.
(3) Connect the electrical wires (5) to the voltmeter (1) with the contact insertion tool.
(4) Install the panel 35VU (2) in its housing.
(5) Turn the four quick-release fasteners (3) by a quarter turn.
(6) Install the plate 13LF (6) on the panel 35VU.
(7) Install the 5 screws (7) and tighten them.
Subtask 24-37-21-865-052
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
-
FOR 3PV1
9PB1
-
FOR 3PV2
9PB2
Subtask 24-37-21-710-050
C. Check of the Battery Voltage
(1) Make sure that the battery voltage comes into view.
5. Close-up
________ Subtask 24-37-21-862-050
A. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
Subtask 24-37-21-410-050
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access panel of the BATTERY power center 105VU.
(3)
Close the access door 822.
(4)
Remove the access platform(s).
1EFF : ALL 1 24-37-21Page 406 1 1 Nov 01/03R 1 1 1CES 1
DC GENERATION - BATTERIES - DESCRIPTION AND OPERATION
_____________________________________________________
1. General
_______
The DC generation is provided by two batteries.
Each of them has a nominal capacity of 23 Ah.
**ON A/C 001-049, 051-099, 101-105, 201-203,
They are mainly used to:
-start the APU in flight and on ground,
-supply AC/DC essential network in emergency configuration during RAT deployment and when the emergency generator is not available (landing gear extended configuration).
Each battery is associated with a Battery Charge Limiter (BCL).
It should be noted that, in normal configuration, the batteries are most of
the time uncoupled from the network during the flight.
R **ON A/C 106-149, 151-199, 204-299, 301-399, 401-499,
They are mainly used to:
-start the APU in flight and on ground,
-supply AC/DC essential network in emergency configuration during RAT deployment and when the emergency generator is not available (CSM/G switched off after landing).
Each battery is associated with a Battery Charge Limiter (BCL).
It should be noted that, in normal configuration, the batteries are most of
the time uncoupled from the network during the flight.
R **ON A/C ALL
2. Component Location
__________________
(Ref. Fig. 001, 002)
-------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA | | | | DOOR | REF.
-------------------------------------------------------------------------------1PB1 BCL-1 124 822 24-38-34 1PB2 BCL-2 124 822 24-38-34 2PB1 BAT-1 126 822 24-38-51 2PB2 BAT-2 126 822 24-38-51 4PB1 HOLDER-BAT 1 FUSE 120VU 212 831 24-38-00 4PB2 HOLDER-BAT 2 FUSE 120VU 212 831 24-38-00 6PB1 CNTOR-LINE, BAT 1 105VU 126 822 24-38-55 6PB2 CNTOR-LINE, BAT 2 105VU 126 822 24-38-55 7PB1 P/BSW-ELEC/BAT 1 35VU 210 831 24-38-00 7PB2 P/BSW-ELEC/BAT 2 35VU 210 831 24-38-00