• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:16来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  2000VU CABIN LIGHT POWER - WINDOW  300LG  H01
 **ON A/C ALL
 2001VU VACUUM TOILET SYSTEM  45MG  A02 

R  **ON A/C 051-051, 
R  2001VU WASTE WIP CARGO DRAIN VALVE  32DU  D08
 **ON A/C 151-199,
 2001VU SEMI AUTO CLS AFT  103MY  D08
 2001VU SEMI AUTO CLS AFT  102MY  D06 
R  **ON A/C 401-499, 
R  2001VU VACUUM TOILET SYSTEM  34MG  A04 
R  2001VU VACUUM TOILET SYSTEM  39MG  A03

 

 **ON A/C ALL
 5. Operation/Control and Indicating
________________________________
 A. Reset of the Circuit Breaker
 -in flight, it is not permitted to close a tripped circuit breaker,
 - on ground, you must not close a tripped circuit breaker without trouble shooting of the related system.


 AC MAIN DISTRIBUTION - DESCRIPTION AND OPERATION
________________________________________________
 1. General
_______
 **ON A/C 001-049, 051-060, 101-102, 201-201,
 (Ref. Fig. 001)
 **ON A/C 061-099, 103-105, 151-158, 202-209,

 (Ref. Fig. 001A)
 **ON A/C 106-149, 159-199, 210-299, 301-399,

 (Ref. Fig. 001B) R **ON A/C 401-499,
R (Ref. Fig. 001C) **ON A/C ALL
 The AC main distribution network corresponds to busbars 1XP and 2XP and their associated sub-busbars.
 2. Component Location
__________________
 **ON A/C 001-049, 051-062, 101-105, 151-152, 201-205,
 (Ref. Fig. 002)
 **ON A/C 063-099, 153-158, 206-209,

 (Ref. Fig. 002A) R **ON A/C 106-149, 159-199, 210-299, 301-399, 401-499,
 (Ref. Fig. 002B, 003) **ON A/C 001-049, 051-060, 101-102, 201-201,


 -------------------------------------------------------------------------------FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA | | | | DOOR | REF.
 -------------------------------------------------------------------------------12XN CNTOR-AC SVCE BUS NORM SPLY 120VU 212 831 24-51-55 15XN1 A/XFMR-115/26VAC, 1 120VU 212 831 24-51-51 15XN2 A/XFMR-115/26VAC, 2 120VU 212 831 24-51-51
 **ON A/C 061-099, 103-105, 151-158, 202-209,
 12XN CNTOR-AC SVCE BUS NORM SPLY 120VU 212 831 24-51-55 15XN1 A/XFMR-115/26VAC, 1 120VU 212 831 24-51-51 15XN2 A/XFMR-115/26VAC, 2 120VU 212 831 24-51-51 27XN CONTACTOR 120 VU 212 831 24-51-00

R **ON A/C 106-149, 159-199, 210-299, 301-399, 401-499,
 12XN CNTOR-AC SVCE BUS NORM SPLY 120VU 212 831 24-51-55 15XN1 A/XFMR-115/26VAC, 1 120VU 212 831 24-51-51 15XN2 A/XFMR-115/26VAC, 2 120VU 212 831 24-51-51 21XN1 CNTOR-115 VAC BUS 1 SPLY 120VU 212 24-51-00 21XN2 CNTOR-115 VAC BUS 2 SPLY 120VU 212 24-51-00 22XN P/BSW-ELEC/COMMERCIAL 35VU 210 24-51-00 25XN1 RECTIFIER-115 VAC BUS 1 SPLY CNTOR 120VU 212 24-51-00 25XN2 RECTIFIER-115 VAC BUS 2 SPLY CNTOR 120VU 212 24-51-00 27XN CONTACTOR 120 VU 212 831 24-51-00
 **ON A/C ALL
 3. Operation/Control and Indicating
________________________________
 The main busbars can be supplied:

 -either by the corresponding generator,
 - or by the other main generator, or by the APU generator or the ground

 power unit by means of the transfer circuit. The major part of the network is supplied with three-phase 115 VAC/400 Hz. A 115/26 VAC single-phase autotransformer supplying a normal 26 VAC/400 Hz sub-busbar (131XP.A and 231XP.A) is connected to each main busbar. Part of the AC main network (212XP, 214XP, 216XP.C) can be supplied directly by the ground power unit in ground service configuration (Ref. 24-42-00, P. Block 1). For each main busbar, a warning is triggered on the ECAM to indicate a loss of supply


 AC Main Distribution - Block Diagram
 Figure 001

R 1EFF : 001-049, 051-060, 101-102, 201-201, 1 24-51-00Page 3/4 1 1 May 01/05 1 1 1CES
1


 AC Main Distribution - Block Diagram
 Figure 001A

R 1EFF : 061-099, 103-105, 151-158, 202-209, 1 24-51-00Page 5/6 1 1 May 01/05 1 1 1CES
1


 AC Main Distribution - Block Diagram
 Figure 001B

R 1EFF : 106-149, 159-199, 210-299, 301-399, 1 24-51-00Page 7/8 1 1 May 01/05 1 1 1CES
1R AC Main Distribution - Block Diagram R Figure 001C


R 1EFF : 401-499, 1 24-51-00Page 9/10 1 1 Aug 01/05 1 1 1CES


 AC Main Distribution - Component Location
 Figure 002

R 1EFF : 001-049, 051-062, 101-105, 151-152, 1 24-51-00Page 11 1201-205, 1Aug 01/05 1 1 1CES 1


 AC Main Distribution - Component Location
 Figure 002A

R 1EFF : 063-099, 153-158, 206-209, 1 24-51-00Page 12 1 1 Aug 01/05 1 1 1CES 1


 AC Main Distribution - Component Location
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源2(115)