(5) Circuit Breaker Panel 2000VU
(a) General The front circuit breaker panel 2000VU faces the FWD passenger/crew door (841) and is located in the center of the cabin ceiling. The circuit breakers are connected to either an AC or a DC power source.
1_ AC Power Supply
- 115 VAC
- 26 VAC
2_ DC Power Supply
- 28 VDC
(b) Description **ON A/C 001-049, 101-105,
(Ref. Fig. 012) **ON A/C 051-051,
(Ref. Fig. 012A) **ON A/C 052-099,
(Ref. Fig. 012B) **ON A/C 106-149, 151-199, 201-299,
(Ref. Fig. 012C) **ON A/C 301-399,
(Ref. Fig. 012D)
1EFF : ALL 1 24-50-00Page 58 1 1 Aug 01/05R 1 1 1CES 1
DISTRIBUTION PANEL 2000VU
Figure 012
1EFF : 001-049, 101-105, 1 24-50-00Page 59 1 1 Aug 01/05R 1 1 1CES 1
DISTRIBUTION PANEL 2000VU
Figure 012A
1EFF : 051-051, 1 24-50-00 Page 60
1 1 Aug 01/05
1R 1
1CES 1
DISTRIBUTION PANEL 2000VU
Figure 012B
R 1EFF : 052-099, 1 24-50-00 Page 61
1 1 Aug 01/05
1 1
1CES 1
DISTRIBUTION PANEL 2000VU
Figure 012C
R 1EFF : 106-149, 151-199, 201-299, 1 24-50-00Page 62 1 1 Aug 01/05 1 1 1CES 1
DISTRIBUTION PANEL 2000VU
Figure 012D
R 1EFF : 301-399, 1 24-50-00 Page 63
1 1 Aug 01/05
1 1
1CES 1
R **ON A/C 401-499,
R (Ref. Fig. 012E) **ON A/C ALL
A simplified drawing shows the front face of the VU. Each circuit breaker head is marked with the FIN and not with the rating. This is to help to identify circuit breakers when they are opened during aircraft maintenance procedures.
NOTE : On the aircraft, the FIN is shown on the rear side of the
____
VU panel.
(6) Circuit Breaker Panel 2001VU
(a) General The circuit breaker panel 2001VU faces the aft passenger door
(842) and is located in the center of the cabin ceiling. The circuit breakers are connected to either an AC or a DC power source.
1 AC Power Supply
_ -115 VAC
-26 VAC
2 DC Power Supply
_ -28 VDC
(b) Description
**ON A/C 001-049, 101-105,
(Ref. Fig. 013)
**ON A/C 051-051,
(Ref. Fig. 013A) R **ON A/C 052-099, 106-149, 151-199, 201-299, 401-499,
(Ref. Fig. 013B)
R DISTRIBUTION PANEL 2000VU
R Figure 012E
R 1EFF : 401-499, 1 24-50-00 Page 65
1 1 Aug 01/05
1 1
1CES 1
DISTRIBUTION PANEL 2001VU
Figure 013
R 1EFF : 001-049, 101-105, 1 24-50-00Page 66 1 1 Aug 01/05 1 1 1CES 1
DISTRIBUTION PANEL 2001VU
Figure 013A
R 1EFF : 051-051, 1 24-50-00 Page 67
1 1 Aug 01/05
1 1
1CES 1
DISTRIBUTION PANEL 2001VU
Figure 013B
R 1EFF : 052-099, 106-149, 151-199, 201-299, 1 24-50-00Page 68 1401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C 301-399,
(Ref. Fig. 013C)
**ON A/C ALL
A simplified drawing shows the front face of the VU. Each circuit breaker head is marked with the FIN and not with the rating. This is to help to identify circuit breakers when they are opened during aircraft maintenance procedures.
NOTE : On the aircraft, the FIN is shown on the rear side of the
____
VU panel.
B. Configuration of Circuit Breakers
(1)
Black head circuit breaker This type of circuit breaker does not have an auxiliary contact. It is standard.
(2)
Green head circuit breaker This type of circuit breaker holds an auxiliary contact connected to SDAC when it is tripped.
(3)
Circuit breaker with a red threaded bush For safety reasons, to avoid that the crew resets it in flight, the C/B is guarded. If it is necessary to open it, the red threaded bush must first be removed, unscrewed with a standard wrench.
(4)
Circuit breaker with a yellow collar Some circuit breakers have a yellow collar to help the crew to find them more easily on the circuit breaker panel.
(5)
For clipped circuit breaker, there are two types of collars, metallic or plastic, secured by lockwire, (Ref. ESPM 20-46-10).
1EFF : ALL 1 24-50-00Page 69 1 1 Aug 01/05R 1 1 1CES 1
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源2(103)