R (3) Control and protective functions
R The GCU controls the connection and disconnection of the power
R provided by the generator to and from the aircraft electrical system.
R This control is provided by means of 3 relays:
R - the Generator Control Relay (GCR) which controls the generator
R excitation,
R - the Power Ready Relay (PRR) which controls the generator line
R contactor and the FAULT warning light in the cockpit,
R - the Servo Valve Relay (SRV) which controls the generator speed by
R means of the servo valve.
R (4) Generator control and protection functions
R The following control or fault signals cause generator shutdown or
R de-energization:
R - No controlled Shutdown recognized upon power-up of the control unit
R - Overvoltage Fault
R - Undervoltage 1 Fault
R - Undervoltage 2 Fault
R - Overfrequency 1 Fault
R - Overfrequency 2 Fault
R - Overfrequency 3 Fault
R - Underfrequency 1 Fault
R - Underfrequency 2 Fault
R - Underspeed
R - Shorted Rotating Diode (PMG to chassis short) Fault
R - Open Cable Fault
R - Differential Protection Fault
R - Overcurrent Fault
R - Delta Overcurrent Fault
R - Phase Sequence Fault with the Power Ready Relay "absent"
R - Servo Valve Deterioration Fault
R - Disconnect Trip Fault
R - Welded GLC Fault
R - GLC Control Circuit Fault
R - Shorted/Open PMG Fault with the Power Ready Relay "absent"
R - Pin Programming Error detected on GCU power-up.
R The generator shall be "reset" when the protective faults
R (identified above) are still not present and one of the following
R occurs:
R - Cold Start (which is defined as POWER-UP RESET or the application
R of 28 volts to the control unit) occurs,
R - Generator Control Switch (GCS) is toggled (OFF to ON).
R The following functions shall be limited to a total of 2 resets
R after which a cold start will be requuired for reset:
R - Overvoltage Fault