Subtask 24-00-00-710-054
 E. Loss of the Electrical Network with the BUS TIE Pushbutton Switch
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ELEC control panel 35VU: - release the BUS TIE pushbutton switch.  On the ELEC control panel 35VU:- the OFF legend of the BUS TIEpushbutton switch comes on. 
 On the lower ECAM DU, on the ELEC page: - total loss of the electrical network. 
 2. On the ELEC control panel 35VU: - push the BUS TIE pushbutton switch.  On the ELEC control panel 35VU:- the OFF legend of the BUS TIEpushbutton switch goes off. 
 On the lower ECAM DU, on the ELEC page: - the electrical network is energized again. 
 Subtask 24-00-00-710-055 
 F. Galley Shedding Logic
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 122VU:  On the lower ECAM DU, on the ELEC page: 
 - open the circuit breaker 7XA.  - the GALLEY SHED indication comes into 
 view. 
 2. On the panel 122VU:  On the lower ECAM DU, on the ELEC page: 
 - close the circuit breaker 7XA.  - the GALLEY SHED indication goes out 
 of view. 
 3. On the ELEC control panel 35VU:  On the lower ECAM DU, on the ELEC page: 
 - release the GALLEY pushbutton  - the GALLEY SHED indication comes into 
 switch.  view. 
 4. On the ELEC control panel 35VU:  On the lower ECAM DU, on the ELEC page: 
 - push the GALLEY pushbutton  - the GALLEY SHED indication goes out 
 switch.  of view.
1EFF : ALL 1 24-00-00Page 507 1 1 Nov 01/02R 1 1 1CES 1
 Subtask 24-00-00-710-056
 G. Transfer Logic of the DC Electrical Network NOTE : This test is for the system 1. For the other system(s), use the
____
 indications between parentheses.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 122VU:  On the lower ECAM DU, on the ELEC page: 
 - open the circuit breaker 3PU1  - no change. 
 (3PU2). 
 2. On the panel 125VU (1254VU):  On the lower ECAM DU, on the ELEC page: 
 - open the circuit breaker 4PU1  - the TR1 (2) stops to energize the DC1 
 (4PU2).  (2) busbar 
 - the DC1 (2) busbar indication stays 
 amber for 5 seconds 
 - the TR1 (2) parameters are 30V, 0A 
 - the DC2 (1) busbar energizes the DC1 
 (2) busbar through the DC BAT busbar 
 - the ESS TR energizes the DC ESS 
 busbar. 
 On the upper ECAM DU: 
 - the TR1 (2) warning comes into view. 
 3. On the panels 122VU and 125VU  No change. 
 (122VU, 124VU): 
 - close the circuit breakers 3PU1 
 (2) and 4PU1 (2). 
 4. On the MCDU, on the ELEC page:  On the MCDU: 
 - push the line key adjacent to  - the TR1 (2) pages comes into view. 
 the TR1 (2) indication. 
 - push the line key adjacent to  On the MCDU: 
 the RESET indication.  - the NO FAULT indication comes into 
 view. 
 On the lower ECAM DU, on the ELEC page: 
 - the TR1 (2) energizes the DC1 (2) 
 busbar 
 - the ESS TR continues to energize the 
 DC ESS busbar.
1EFF : ALL 1 24-00-00Page 508 1 1 Nov 01/02R 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
5.
 On the panel 125VU:
- open then close the circuit breaker 1XC.
6.
 On the panel 123VU:
- open the circuit breaker 2PU1 (2).
7.
 On the panel 123VU:
-close the circuit breaker 2PU1 (2).
 8.
 On the MCDU, on the ELEC page:
-
push the line key adjacent to the TR1 (2) indication.
 -
push the line key adjacent to the RESET indication.
On the upper ECAM DU:
 -
the TR1 (2) FAULT warning goes out of view.
On the lower ECAM DU, on the ELEC page:
-
the DC1 busbar energizes the DC ESSbusbar.
On the lower ECAM DU, on the ELEC page:
-
the TR1 (2) stops to energize the DC1
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源1(35)