R  To do a torque check of the IDG QAD adapter tension bolt without component 
R  removal. 
R  2. Job Set-up Information______________________ 
R  A. Fixtures, Tools, Test and Support Equipment 
R  -------------------------------------------------------------------------------
R  REFERENCE QTY DESIGNATION 
R  -------------------------------------------------------------------------------
R  No specific lockwire 
R  No specific warning notice 
R  No specific Torque Wrench : range 2.00 to 26.00 lbf.ft 
R  (0.20 to 3.60 m.daN) 
R  B. Consumable Materials 
R  -------------------------------------------------------------------------------
R  REFERENCE DESIGNATION 
R  -------------------------------------------------------------------------------
R  Material No. 03-002 GB DEF-STAN 91-101 
R  LUBRICATING OIL TURBINE ENGINE SYNT BASE 
R  (Ref. 20-31-00) 
R  Material No. 05-027 USA MIL-L-81309 
R  RUST INHIBITOR(FOR CORROSION USE 15-004) 
R  (Ref. 20-31-00) 

R 1EFF : 401-499, 1 24-21-00Page 620 1 1 Aug 01/05 1 1 1CES 1R C. Referenced Information


R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 24-21-41-000-040 R R 24-21-51-000-040 R R 71-13-00-010-040 R 71-13-00-410-040 R 24-21-00-991-912 R 24-21-00-991-913
R 3. Job Set-up
__________
R Subtask 24-21-00-941-073
R A. Safety Precautions Removal of the Quick Attach/Detach (QAD) Adapter of the IDG (4000XU) Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) Opening of the Fan Cowl Doors Closing of the Fan Cowl Doors Fig. 604 Fig. 605
R (1) On the center pedestal, on the ENG panel 115VU:
R (a) Put a warning notice in position to tell persons not to start the R engine.
R (2) Make sure that the engine 1(2) shutdown occurred not less than 5 R minutes before you do this procedure.
R (3) On the overhead maintenance panel 50VU:
R (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) R pushbutton switch is off.
R (b) Put a warning notice in position to tell persons not to energize R the FADEC 1(2).
R Subtask 24-21-00-010-083
R B. Open the right fan-cowl door (Ref. TASK 71-13-00-010-040): R - FOR 1000EM1 R 438AR R - FOR 1000EM2 R 448AR


R  4. Procedure_________ 
R  (Ref. Fig. 604/TASK 24-21-00-991-912) 
R  Subtask 24-21-00-020-077 
R  A. Removal of the Lockwire 
R  WARNING : WEAR GOGGLES WHEN YOU REMOVE OR INSTALL THE LOCKWIRE. CUT,_______ 
R  REMOVE AND DISCARD THE LOCKWIRE AS YOU DO THE TASK. LOOSE 
R  LOCKWIRE CAN CUT OR BLIND YOU. 
R  (1) Cut and remove the lockwire (1) from the tension bolt (2). 
R  Subtask 24-21-00-640-060 
R  B. Lubrication of the QAD Adapter and the Tension Bolt 
R  (1) Apply SPECIAL MATERIALS (Material No. 05-027) with a spray to the QAD 
R  ring (3), the mating surface between the QAD adapter and the QAD 
R  ring,in the zone where you can get access. 
R  (2) Lubricate the tension bolt (2) with the OILS (Material No. 03-002). 
R  Subtask 24-21-00-220-051 
R  C. Torque Check of the QAD Adapter Tension-Bolt 
R  (Ref. Fig. 605/TASK 24-21-00-991-913) 
R  (1) Measure the torque value on the tension bolt (2) 
R  If the torque on the tension bolt (2) of the QAD adapter is less than 
R  15 lbf.ft (2.03 m.daN), adjust the QAD ring (3). To do this, tap the 
R  edge of the QAD ring (3) that you can see with a brass drift to make 
R  sure that the torque value you measure is correct. TORQUE the tension 
R  bolt to between 22 and 26 lbf.ft (2.98 and 3.52 m.daN). 
R  (2) Shake the antidrive end of the IDG to do a check of the QAD adapter. 
R  If the IDG is loose, remove the IDG mounting flange (Ref. TASK 24-21-
R  51-000-040) and the QAD adapter (Ref. TASK 24-21-41-000-040). 
R  Tap the edge of the QAD ring (3) again and do the torque check again 
R  until the torque value does not decrease by more than 2 lbf.ft (0.27 
R  m.daN). 
R  (3) Do a check of the distance between the ring lug and the bracket of 
R  the QAD ring. If the distance is less than 0.312 in. (7.9 mm), 
R  replace the IDG (Ref. TASK 24-21-51-000-040) and the QAD adapter 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源1(67)