2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific container 5.7 l (1.5 USgal)
No specific warning notice
No specific Torque Wrench : range 36.00 to 220.00 lbf.in
(0.40 to 2.60 m.daN)
DH13PM 1 TANK - ENGINE OIL FILLING UP
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. CP8001 * lockwire 0.032 in. (0.80 mm) dia. (Ref. 70-30-00) Material No. CP8002 * lockwire 0.032 in. (0.80 mm) dia. (Ref. 70-30-00)
Material No. 03-002 GB DEF-STAN 91-101
LUBRICATING OIL TURBINE ENGINE SYNT BASE
(Ref. 20-31-00)
C. Expendable Parts
-------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
2 O-ring 24-21-51 02 -020 2 O-ring 24-21-51 02A-020 R 2 O-ring 24-21-51 02D-020
D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-13-24-612-041 IDG Servicing - Filling of the IDG with Oil or Addition of Oil after a Level Check
24-21-51-000-041 24-21-51-400-041 24-42-00-861-001 Removal of the IDG Oil Filter(s)Installation of the IDG Oil Filter(s)Energize the Ground Service Network from the External Power
24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power
71-00-00-710-001 71-00-00-710-003 71-13-00-010-040 71-13-00-410-040 78-30-00-081-041 Dry Motoring CheckEngine Automatic StartOpening of the Fan Cowl DoorsClosing of the Fan Cowl DoorsMake the Thrust Reverser Serviceable after
Maintenance
78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 24-21-00-991-304 **ON A/C 401-499,
R R 24-21-00-991-304-A **ON A/C ALL
3. Job Set-up__________
Fig. 304
Fig. 304A
Subtask 24-21-00-861-063
A. Energize the ground service network (Ref. TASK 24-42-00-861-001).
Subtask 24-21-00-941-071
B. Safety Precautions
(1)
On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice in position to tell persons not to start the engine.
(2)
Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3)
On the overhead maintenance panel 50VU:
(a)
Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b)
Put a warning notice in position to tell persons not to energize the FADEC 1(2).
Subtask 24-21-00-010-081
C. Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
-
FOR 1000EM1
437AL, 438AR,
-
FOR 1000EM2
447AL, 448AR.
Subtask 24-21-00-481-061
D. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
4. Procedure
_________ R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
(Ref. Fig. 304/TASK 24-21-00-991-304) R **ON A/C 401-499,
R (Ref. Fig. 304A/TASK 24-21-00-991-304-A)
Oil Type Change - IDG
Figure 304/TASK 24-21-00-991-304
R Oil Type Change - IDG
R Figure 304A/TASK 24-21-00-991-304-A
1EFF : 401-499, 1 24-21-00 Page 341
1 1 Aug 01/05
1 1
1CES 1
R **ON A/C ALL
Subtask 24-21-00-864-059
A. Depressurization of the IDG Case WARNING : POINT THE OVERFLOW DRAIN HOSE INTO A CONTAINER WHEN YOU CONNECT
_______ THE HOSE TO THE OVERFLOW DRAIN VALVE. THIS WILL PREVENT BURNS FROM THE HOT OIL SPRAY. HOT OIL CAN CAUSE BURNS TO EYES AND SKIN.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源1(56)