 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s)
 No specific warning notice
 No specific container 2.0 l (0.5283 USgal)
 No specific access platform 2.5 m (8 ft. 2 in.)
 98D49207537001 1 CABLE - SAFETY, APU GENERATOR

 

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION ------------------------------------------------------------------------------- **ON A/C ALL
29-00-00-864-001 49-90-00-600-002 49-90-00-600-005 49-90-00-600-008 49-91-41-200-001 49-91-41-200-002 49-91-41-920-001  Put the Related Hydraulic System in the Depressurized Configuration before Maintenance ActionOil Change (Drain Method) (GTCP 36-300)Oil Change (Drain Method) (APS 3200)Oil Change (Drain Method) (131-9(A))Remove and discard Alternator Scavenge Filter Element (8069KM) (GTCP 36-300)Inspection and Replacement of Oil Filters (8069KM) and (8076KM) (131-9(A))Remove and Discard Pressure Oil Filter-Element
 49-91-41-920-002 49-91-45-200-002 52-41-00-010-001  (8076KM) (APS 3200)Replace AC-Generator Scavenge Filter-Element (8069KM) (APS 3200)Remove and discard Lube Filter Element (GTCP 36-300)Open the APU Doors for Access 

R  **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 24-23-51-991-001-A **ON A/C 051-099, Fig. 401
R  24-23-51-991-001 Fig. 401A **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 24-23-51-991-003-A **ON A/C 051-099, Fig. 402
 24-23-51-991-003  Fig. 402A

 

 3. Job Set-up
__________
 Subtask 24-23-51-860-050

 A. Aircraft Maintenance Configuration
 (1)
 On the panel 25VU, make sure that the APU MASTER SW pushbutton switch is off.

 (2)
 Put a warning notice in the cockpit to tell persons not to start the APU.

 (3)
 Make sure that ground fire extinguishing equipment is available.

 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-00-00-864-001).

 

 Subtask 24-23-51-865-050
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
 Subtask 24-23-51-010-050
 C. Get Access
 (1)
 Put the access platform in position below the APU access doors 315AL and 316AR.

 (2)
 Open the APU access doors 315AL and 316AR (Ref. TASK 52-41-00-010-001).


 4. Procedure
_________ R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 401/TASK 24-23-51-991-001-A)


 APU Generator 8XS. Figure 401/TASK 24-23-51-991-001-A
R 1EFF : 001-049, 101-149, 151-199, 201-299, 1 24-23-51Page 404 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C 051-099,


 (Ref. Fig. 401A/TASK 24-23-51-991-001) R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 402/TASK 24-23-51-991-003-A)
 **ON A/C 051-099,

 (Ref. Fig. 402A/TASK 24-23-51-991-003)
 **ON A/C ALL

 Subtask 24-23-51-020-050
 A. Removal of the APU Generator WARNING : DO NOT CAUSE DAMAGE TO THE THREADS OF THE SET SCREWS WHEN YOU
_______ REMOVE OR INSTALL THE GENERATOR. THE GENERATOR WEIGHS APPROXIMATELY 23kg (50.7lb).
 (1)
 Put the CABLE - SAFETY, APU GENERATOR on the generator to get a safe condition when you remove the generator.

 (2)
 Disconnect the electrical connector (12) from the APU generator (4).

 (3)
 Put blanking caps on the disconnected electrical connectors.

 (4)
 Remove the screws (17),the washers (16) and the cover plate (18).

 (5)
 Remove the nuts (19), the four electrical cables (20) and the washers (21).

 (6)
 Put a container below the generator (4) to collect the oil which will flow when you remove the drain plug (14).

 (7)
 Remove and discard the lockwire from the drain plug (14) and remove it. Take care to collect the drained oil in the container.
 