(2) busbar
 -
the DC1 (2) busbar indication stays amber for 5 seconds
 -
the TR1 (2) parameters are 0V, 0A
 -
the DC2 (1) busbar energizes the DC1
(2) busbar through the DC BAT busbar
 -
the ESS TR energizes the DC ESS busbar.
On the upper ECAM DU:
 -
the TR1 (2) FAULT warning comes into view.
On the lower ECAM DU, on the ELEC page:
-
the TR1 (2) parameters are 30V, 0A.
On the MCDU:
-
the TR1 (2) page comes into view.
On the MCDU:
-
the NO FAULT indication comes into view.
On the SD, on the ELEC page:
 -
the TR1 (2) energizes the DC1 (2) busbar
 -
the ESS TR continues to energize the DC ESS busbar.
On the upper ECAM DU:
 -
the TR1 (2) FAULT warning goes out of view.
 1EFF : ALL 1 24-00-00Page 509 1 1 Nov 01/02R 1 1 1CES 1
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
9.
 On the panel 125VU:
- open then close the circuit breaker 1XC.
10.
 On the panel 122VU: - open the circuit breaker 9PC.
11.
 On the control panel 122VU:
-close the circuit breaker 9PC.
12.
 On the panel 125VU:
- open then close the circuit breaker 1XC. 
Subtask 24-00-00-710-057On the lower ECAM DU, on the ELEC page:
-
the DC1 busbar energizes the DC ESSbusbar.
On the lower ECAM DU, on the ELEC page:
-
the DC2 busbar energizes the DC BAT busbar (the DC1 busbar stops to energize the DC BAT busbar)
 -
the ESS TR energizes the DC ESS busbar.
On the lower ECAM DU, on the ELEC page:
-
the DC1 busbar energizes the DC BAT busbar
 -
the ESS TR energizes the DC ESS busbar.
On the lower ECAM DU, on the ELEC page:
-
the DC1 busbar energizes the DC ESSbusbar.
 H. Test of the DC EMER CONFIG Warning
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panels 106VU and 49VU: - open the circuit breakers 68WV and 12WV.  On the lower ECAM DU, on the ELEC page:- the DC ESS busbar indication comes onamber. 
 On the upper ECAM DU: - the DC EMER CONFIG and EMER ELEC PWR 
 ... MAN ON warnings come into view. 
 2. On the panels 106VU and 49VU: - close the circuit breakers 68WV  On the lower ECAM DU, on the ELEC page:- the DC ESS busbar indication becomes 
 and 12WV.  green. 
 On the upper ECAM DU: - the DC EMER CONFIG and EMER ELEC PWR 
 ... MAN ON warnings go out of view.
1EFF : ALL 1 24-00-00Page 510 1 1 Nov 01/02R 1 1 1CES 1
 Subtask 24-00-00-710-058
 J. Emergency Logic with the Batteries
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
 Make sure that the voltage of the batteries 1 and 2 is more than 25.5V.
 2.
 On the ELEC control panel 35VU:
-release then push the BAT1 pusbutton switch.
3.
 On the ELEC control panel 35VU:
-release then push the BAT2 pushbutton switch.
4.
 On the ELEC control panel 35VU:
-release the BAT1 and BAT2 
pusbutton switches.
On the EMER ELEC PWR control panel 21VU:
 -push and hold the EMER GEN TEST pushbutton switch.
 On the ELEC control panel 35VU:
 -release the BUS TIE pushbutton switch.
 On the lower ECAM DU: 
-get the ELEC page and make sure that it stays in view.
On the lower ECAM DU, on the ELEC page:
-
the green line between the DC BATbusbar and the BAT1 indications come into view
 -
the load current is < 150A then decreases
 -
the green line goes out of view when the load current is < 4A.
On the lower ECAM DU, on the ELEC page:
-
the green line between the DC BATbusbar and the BAT2 indications comes into view
 -
the load current is < 150A then decreases
 -
the green line goes out of view when the load current is < 4A.
On the ELEC control panel 35VU:
-
the OFF legend of the BAT1 and BAT2pushbutton switches comes on.
Total loss of the normal electrical
network.
On the lower ECAM DU:
1EFF : ALL 1 24-00-00Page 511 1 1 Nov 01/02R 1 1 1CES 1 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源1(36)