R  Subtask 24-21-51-720-055 
R  Q. Check of the Oil Leaks and the Electricals Characteristics 
R  (1) At the first engine start-up: 
R  (a) Make sure that the IDG operates correctly: 
R  On the ECAM control panel,push the ELEC key to get the ELEC page 
R  on the lower ECAM DU: 
R  - make sure that the voltage is 115 VAC 
R  - make sure that the frequency is 400 Hz plus or minus 5 HZ. 
R  NOTE : If the IDG was removed after an IDG disconnection, do a____ 
R  GCU reset at the first engine start-up at idle. To do 
R  this, on the ELEC control panel 35VU, push then release 
R  the related ELEC/GEN pushbutton switch (3XU). 
R  (2) If the IDG is not connected, make sure that the CMS message IDGx 
R  (Ex-4000XU) RECONFIG is shown on the EPGS GROUND REPORT page. 
R  (a) Make sure that the related GCU is energized. 
R  1 On the ELEC control panel 35VU, release (OFF) then push the_ 
R  related ELEC/GEN pushbutton switch (3XU) to do a reset of the 
R  GCU. 
R  2 On the SD, on the ELEC page, make sure that the line_ 
R  connection between the IDG1 (2) and the related AC busbar is 
R  shown green.

 

R  (b) If the related engine is stopped, on the ELEC control panel 35VU, 
R  release then push the related ELEC/GEN pushbutton switch (3XU). 
R  1 Start the engine._ 
R  2 On the SD, on the ELEC page, make sure that the line_ 
R  connection between the IDG1 (2) and the related busbar is 
R  shown green. 
R  (c) If the IDG1 (2) is not connected after the GCU reset, do a check 
R  for other CMS fault messages related to the IDG. 
R  (3) Make sure that there are no oil leaks. 
R  - Do a check of the oil level. (Ref. TASK 12-13-24-612-041) 
R  5. Close-up________ 
R  Subtask 24-21-51-410-059 
R  A. Close Access 
R  (1) Make sure that the work area is clean and clear of tool(s) and other 
R  items. 
R  (2) Close the fan cowl doors (Ref. TASK 71-13-00-410-040): 
R  - FOR 1000EM1 
R  437AL, 438AR 
R  - FOR 1000EM2 
R  447AL, 448AR 
R  (3) Remove the warning notice(s).

 


R **ON A/C ALL
 TASK 24-21-51-000-041 Removal of the IDG Oil Filter(s) WARNING : BE CAREFUL WHEN YOU WORK ON THE ENGINE COMPONENTS IMMEDIATELY AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS CAN STAY HOT FOR UP TO ONE HOUR.
 WARNING : WEAR GOGGLES, INSULATED GLOVES AND OTHER PROTECTIVE CLOTHES.
_______
 HOT OIL CAN BURN YOUR EYES AND SKIN.
 IF OIL TOUCHES YOUR EYES OR SKIN, GET MEDICAL AID.

 CAUTION : DO NOT LET ENGINE OIL FALL ON THE ENGINE. UNWANTED OIL MUST BE
_______ REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH THE OIL CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking cap
 No specific container 1.5 USgal (5.68 l)
 No specific warning notice

 

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-13-24-680-040 24-21-00-210-044 71-13-00-010-040  Draining of the Oil from the IDGInspection of the Filter Element(s)Opening of the Fan Cowl Doors 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
R  24-21-51-991-304  Fig. 409 
R  **ON A/C 401-499, 
R  24-21-51-991-304-A  Fig. 409A 
R  **ON A/C ALL
 3. Job Set-up__________
 Subtask 24-21-51-941-057
 A. Safety Precautions
 (1) On the center pedestal, on the ENG panel 115VU:
 (a) Put a warning notice in position to tell persons not to start the engine.
 (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
 
中国航空网 www.aero.cn