R  (b) If the related engine is stopped, on the ELEC control panel 35VU,  
R  release then push the related ELEC/GEN pushbutton switch (3XU).  
R  1 Start the engine._  
R  2 On the SD, on the ELEC page, make sure that the line_  
R  connection between the IDG1 (2) and the related busbar is  
R  shown green.  
R  (c) If the IDG1 (2) is not connected after the GCU reset, do a check  
R  for other CMS fault messages related to the IDG.  
R  (3) Make sure that there are no oil leaks.  
R  - Do a check of the oil level. (Ref. TASK 12-13-24-612-041)  
R  5. Close-up________  
R  Subtask 24-21-51-410-059  
R  A. Close Access  
R  (1) Make sure that the work area is clean and clear of tool(s) and other  
R  items.  
R  (2) Close the fan cowl doors (Ref. TASK 71-13-00-410-040):  
R  - FOR 1000EM1  
R  437AL, 438AR  
R  - FOR 1000EM2  
R  447AL, 448AR  
R  (3) Remove the warning notice(s).
R **ON A/C ALL
 TASK 24-21-51-000-041 Removal of the IDG Oil Filter(s) WARNING : BE CAREFUL WHEN YOU WORK ON THE ENGINE COMPONENTS IMMEDIATELY AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS CAN STAY HOT FOR UP TO ONE HOUR.
 WARNING : WEAR GOGGLES, INSULATED GLOVES AND OTHER PROTECTIVE CLOTHES.
_______
 HOT OIL CAN BURN YOUR EYES AND SKIN.
 IF OIL TOUCHES YOUR EYES OR SKIN, GET MEDICAL AID.
 CAUTION : DO NOT LET ENGINE OIL FALL ON THE ENGINE. UNWANTED OIL MUST BE
_______ REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH THE OIL CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
 1.
 Reason for the Job
__________________
 Self Explanatory
 2.
 Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking cap
 No specific container 1.5 USgal (5.68 l)
 No specific warning notice
 B. Referenced Information 
 -------------------------------------------------------------------------------REFERENCE DESIGNATION ------------------------------------------------------------------------------- 
12-13-24-680-040 24-21-00-210-044 71-13-00-010-040  Draining of the Oil from the IDGInspection of the Filter Element(s)Opening of the Fan Cowl Doors  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,  
R  24-21-51-991-304  Fig. 409  
R  **ON A/C 401-499,  
R  24-21-51-991-304-A  Fig. 409A  
R  **ON A/C ALL 
 3. Job Set-up__________ 
 Subtask 24-21-51-941-057 
 A. Safety Precautions 
 (1) On the center pedestal, on the ENG panel 115VU: 
 (a) Put a warning notice in position to tell persons not to start the engine. 
 (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源1(91)