R 1EFF : 401-499, 1 24-22-17Page 416 1 1 Aug 01/05 1 1 1CES 1R B. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 24-22-17-991-001-A R FOR FIN 41XU1, 41XU2 R 25-54-12-000-002 R R 52-30-00-860-001 R R 24-22-17-991-002 R FOR FIN 51XU1, 51XU2 R 24-22-17-991-005
R 3. Job Set-up
__________
R Subtask 24-22-17-010-054
R A. Get Access R FOR 41XU1, 41XU2 Fig. 401A
Removal of the Ceiling Panels in the FWD Cargo Compartment Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump Fig. 402
Fig. 405
R (1) Open the cargo compartment door 825AR (Ref. TASK 52-30-00-860-001).
R (2) Put an access platform in position at the cargo compartment door R 825AR. R (3) In the zone 130, remove the ceiling panels 131MC, 131NC, 131PC
R (Ref. TASK 25-54-12-000-002).
R Subtask 24-22-17-010-055
R B. Get Access
R FOR 51XU1, 51XU2
R (1) Put an access platform in position at the access door 822.
R (2) Open the access door 822.
R 1EFF : 401-499, 1 24-22-17Page 417 1 1 Aug 01/05 1 1 1CES 1
R Subtask 24-22-17-941-052
R C. Safety Precautions
R (1) Make sure that the external power connector is not connected to the
R aircraft external power receptacle.
R (2) FOR 41XU1, 41XU2, 51XU1, 51XU2
R Put warning notice(s) in position on the access door 121AL to tell
R persons not to connect the external power connector to the aircraft
R external power receptacle.
R (3) In the cockpit, on the ELEC panel 35VU, make sure that these
R pushbutton switches are released:
R - BAT1, BAT2,
R - APU GEN,
R - GEN1, GEN2,
R - EXT PWR.
R (4) In the cockpit, put warning notice(s) in position to tell persons not
R to operate the pushbutton switches on these overhead panels:
R - 21VU (EMER ELEC PWR section),
R - 25VU (APU section),
R - 35VU (ELEC).
R 4. Procedure_________
R (Ref. Fig. 401A/TASK 24-22-17-991-001-A)
R Subtask 24-22-17-020-053
R A. Removal of the AC Current Transformer
R FOR 41XU1, 41XU2
R (Ref. Fig. 402/TASK 24-22-17-991-002)
R (1) Remove the screws (6).
R (2) Remove the cover (7) to get access to the terminal block (5).
R NOTE : You must identify (also with the indications on the current____
R transformer) and disconnect only the cables which go through
R the current transformer.
R (3) Remove the nuts (1), the washers (2) and the cables (3) and (4) from
R the studs of the terminal block (5).
R 1EFF : 401-499, 1 24-22-17Page 418 1 1 Aug 01/05 1 1 1CES 1
R (4) Disconnect the electrical connector (11) from the current transformer
R (10).
R (5) Put blanking caps on the disconnected electrical connector (11) and
R electrical receptacle (12).
R (6) Remove the screws (8) and the washers (9) from the current
R transformer (10).
R (7) Move the current transformer (10) along the cables to remove it.
R Subtask 24-22-17-020-054
R B. Removal of the AC Current Transformer
R FOR 51XU1, 51XU2
R (Ref. Fig. 405/TASK 24-22-17-991-005)
R (1) Record the location and the color of the cables of each bundle which
R goes through the current transformer (1).
R (2) Remove the screws (7) and the washers (8) from the studs of the
R module 30XN1 (30XN2).
R (3) Disconnect the cables (9) from the studs of the module 30XN1 (30XN2).
R NOTE : You must identify (also with the indications on the current____
R transformer) and disconnect only the cables which go through
R the current transformer.
R (4) Remove the nuts (10) and the washers (11) from the studs of the
R module 30XN1 (30XN2).
R (5) Disconnect the cables (12) from the studs of the module 30XN1
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源1(116)