 Make sure that the warning notices are in position.

 (2)
 Put the safety barriers in position.

 (3)
 Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).


 (4)
 Pressurize the Blue hydraulic system
 (Ref. TASK 29-10-00-863-003).

 

 Subtask 24-20-00-010-050
 B. Get access to the Avionics Compartment
 (1)
 Put an access platform at the access door 812 of the avionics compartment.

 (2)
 Open the access door 812.

 


 Subtask 24-20-00-865-050
 C. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
106VU CSM/G /EV/MAN/SPLY 6XE B04
 4. Procedure
_________
 **ON A/C 001-049, 051-061, 101-102, 201-202,

 (Ref. Fig. 401/TASK 24-20-00-991-001) R **ON A/C 062-099, 103-149, 151-199, 203-299, 301-399, 401-499,
 (Ref. Fig. 401A/TASK 24-20-00-991-001-A)
 **ON A/C ALL

 WARNING : MAKE SURE THAT THE RAT TRAVEL RANGE IS CLEAR BEFORE YOU
_______
 EXTEND/RETRACT THE RAT.

 Subtask 24-20-00-710-053
 A. Extension of the RAT NOTE : Make sure that a second mechanic examines the extension of the RAT
____
 before you push the MAN ON/AUTO switch.

 NOTE : Do not operate the deployment solenoids of the RAT for more than
____ 60 seconds. You can operate these solenoids more than one time during the test. When the total operation time (solenoid energized) is 60 seconds, a 30 minutes cooling time is mandatory.


 RAT Control
 Figure 401/TASK 24-20-00-991-001

R 1EFF : 001-049, 051-061, 101-102, 201-202, 1 24-20-00Page 404 1 1 May 01/05 1 1 1CES 1


 RAT control Figure 401A/TASK 24-20-00-991-001-A
R 1EFF : 062-099, 103-149, 151-199, 203-299, 1 24-20-00Page 405 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 (1) Do this test:


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the overhead panel 21VU:  In the zone 195:
 -in the EMER ELEC PWR section, lift  the RAT extends.
 the guard and push the MAN ON/AUTO
 switch.


R **ON A/C 001-049, 051-061, 101-102, 201-202,
 Subtask 24-20-00-710-054
 B. Retraction of the RAT:
 (1) Do this test:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
In the zone 195:
 -set the blade of the RAT manually
 in line with the leg assembly
 (index position).

 NOTE : Retraction is not possible if
____
 the index is not adjacent to
 the arrow.

 At the access door 197EB:
 - open the access door 197EB (ground
 service panel of the Blue system),

 - open the door of the RAT ground
 control-unit 2815GE to get access
 to the RAT control panel.

 1. On the RAT control panel: At the zone 195:
 -lift the red guard and set the  - the RAT goes back in its housing, ARM switch to the up position, - make sure that the warning light goes
 -set the STOW switch to the  off after the retraction of the RAT, right position (STOW) and keep


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------it in this position. NOTE : if the RAT does not retract, do
____ again the full test procedure (RAT retraction).
 2. On the RAT control panel:
 -release the STOW switch.
 -set the ARM switch to the down
 position and close the red
 guard,

 -close and lock the door of the
 RAT ground control-unit 2815GE,

 -Close the access door 197EB
 (ground service panel of the
 Blue system).


R **ON A/C 062-099, 103-149, 151-199, 203-299, 301-399, 401-499,
 Subtask 24-20-00-710-054-A
 B. Retraction of the RAT:
 CAUTION : MAKE SURE THAT THE RAT IS RETRACTED COMPLETELY BEFORE YOU
_______ RELEASE THE "RAT STOW" SWITCH . IF THE RETRACTION SEQUENCE STOPS JUST BEFORE THE RAT ENTERS THE BAY IN THE FAIRTING THIS WILL CAUSE DAMAGE TO THE RAT ACTUATOR.
 (1) Do this test:
 