B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
Material No. CP8002 * Lockwire CRS 0.032in. (0.8mm) dia (Ref. 70-30-00)
Material No. 03-002 GB DEF-STAN 91-101
LUBRICATING OIL TURBINE ENGINE SYNT BASE
(Ref. 20-31-00)
Material No. 11-002 USA MIL-PRF-680
DRY CLEANING SOLVENT (VARSOL/WHITE SPIRIT)
(Ref. 20-31-00)
C. Expendable Parts
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------
2 packing 24-21-51 05 -030 5 packing 24-21-51 05 -060 15 packing 24-21-51 05 -080 17 packing 24-21-51 05 -100 42 O-ring 24-21-51 03 -010 44 O-ring 24-21-51 03 -020
D. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
12-13-24-612-041 IDG Servicing - Filling of the IDG with Oil or Addition of Oil after a Level Check 24-21-00-710-040 Operational Test of the IDG Disconnect and Reconnect
(Reset) Function - Engine Static 24-21-00-730-040 System Test of the IDG Frequency (P/N 740119) 24-21-41-000-040 Removal of the Quick Attach/Detach (QAD) Adapter of
the IDG (4000XU)
24-21-51-000-040 Removal of the Integrated Drive Generator -IDG
1(2),(4000XU)
71-13-00-010-040 Opening of the Fan Cowl Doors
71-13-00-410-040 Closing of the Fan Cowl Doors
24-21-51-991-300 Fig. 401
R 24-21-51-991-301 Fig. 403 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R 24-21-51-991-302 Fig. 405 R 24-21-51-991-303 Fig. 406
3. Job Set-up
__________
Subtask 24-21-51-860-054
A. Aircraft Maintenance Configuration
(1)
On the center pedestal, on the ENG panel 115VU, make sure that a warning notice is in position to tell persons not to start the engine.
(2)
On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a warning notice is in position to tell persons not to energize the FADEC 1(2).
Subtask 24-21-51-865-057
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 1000EM1, 4000XU
122VU ELEC/GCU/1 2XU1 T26
122VU ELEC/IDG1/DISC 1XT T24
FOR 1000EM2, 4000XU 122VU ELEC/GCU/2 2XU2 T27 122VU ELEC/IDG2/DISC 2XT T25