R 1EFF : 401-499, 1 24-21-51Page 431 1 1 Aug 01/05 1 1 1CES 1R B. Consumable Materials
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R Material No. CP8002 *
R Lockwire CRS 0.032in. (0.8mm) dia (Ref. 70-30-00)
R Material No. 03-002 GB DEF-STAN 91-101
R LUBRICATING OIL TURBINE ENGINE SYNT BASE
R (Ref. 20-31-00)
R Material No. 11-002 USA MIL-PRF-680
R DRY CLEANING SOLVENT (VARSOL/WHITE SPIRIT)
R (Ref. 20-31-00)
R C. Expendable Parts
R -------------------------------------------------------------------------------R FIG.ITEM |DESIGNATION |IPC-CSN R -------------------------------------------------------------------------------
R 2 packing
R 5 packing
R 15 packing
R 17 packing
R 42 O-ring
R 44 O-ring
R D. Referenced Information
24-21-51 05 -030 24-21-51 05 -060 24-21-51 05 -080 24-21-51 05 -100 24-21-51 02D-090 24-21-51 02D-010
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 12-13-24-612-041
R
R 24-21-00-710-040
R
R 24-21-41-000-040
R
R 24-21-51-000-040
R
R 71-13-00-010-040
R 71-13-00-410-040
R 24-21-51-991-305
R 24-21-51-991-306
R 24-21-51-991-307
IDG Servicing - Filling of the IDG with Oil or Addition of Oil after a Level Check Operational Test of the IDG Disconnect and Reconnect (Reset) Function - Engine Static Removal of the Quick Attach/Detach (QAD) Adapter of the IDG (4000XU) Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) Opening of the Fan Cowl Doors Closing of the Fan Cowl Doors Fig. 402 Fig. 404 Fig. 407
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R 24-21-51-991-308 Fig. 408
R 3. Job Set-up__________
R Subtask 24-21-51-860-057
R A. Aircraft Maintenance Configuration
R (1) On the center pedestal, on the ENG panel 115VU, make sure that a
R warning notice is in position to tell persons not to start the
R engine.
R (2) On the overhead maintenance panel 50VU, make sure that the ON legend
R of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure
R that a warning notice is in position to tell persons not to energize
R the FADEC 1(2).
R Subtask 24-21-51-865-061
R B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
R tagged
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R FOR 1000EM1, 4000XU
R 122VU ELEC/GCU/1 2XU1 T26
R 122VU ELEC/IDG1/DISC 1XT T24
R FOR 1000EM2, 4000XU
R 122VU ELEC/GCU/2 2XU2 T27
R 122VU ELEC/IDG2/DISC 2XT T25
R Subtask 24-21-51-010-062
R C. Make sure that the fan cowl doors are open (Ref. TASK 71-13-00-010-040):
R - FOR 1000EM1
R 437AL, 438AR
R - FOR 1000EM2
R 447AL, 448AR
R 4. Procedure_________
R (Ref. Fig. 402/TASK 24-21-51-991-305)
R WARNING : WEAR GOGGLES WHEN YOU REMOVE OR INSTALL THE LOCKWIRE. CUT, REMOVE_______
R AND DISCARD THE LOCKWIRE AS YOU DO THE TASK. LOOSE LOCKWIRE CAN
R CUT OR BLIND YOU.
R Subtask 24-21-51-640-063
R A. Lubrication of the Consumable Materials and QAD Adapter
R (1) Lubricate the QAD adapter ring threads, lugs and the tension bolt
R (43) with the OILS (Material No. 03-002).
R (2) Lubricate the new O-ring (42) and O-ring (44) with the OILS (Material
中国航空网 www.aero.cn
航空翻译 www.aviation.cn