_______ CAUSE DAMAGE TO THE ADJACENT WEBS OF THE GENERATOR HOUSING.
(a) Make sure that the HOIST - MINILIFT holds the weight of the generator (4) and loosen the bolts (15) until the generator can be rotated.
(13) Turn the generator CAUTION : BE CAREFUL WHEN YOU TURN THE GENERATOR. TOOLS THAT YOU USE
_______ TO HELP YOU MOVE THE APU GENERATOR CAN EASILY CAUSE DAMAGE TO THE HOUSING. DO NOT APPLY FORCE TO THE WEBS AT THE MAIN FLANGE.
(a) Turn the generator (4) counterclockwise and withdraw it from the gear-box splined drive.
(14)
Lower the generator from the APU compartment and disconnect the shackle from the lifting eye (23).
(15)
Remove the lifting eye (23).
(16)
Remove and discard the O-rings (9) and (10).
(17)
Remove the countersunk screws (1) and the seal plate (7), if a new generator must be installed.
1EFF : ALL 1 24-23-51Page 418 1 1 May 01/05R 1 1 1CES 1
Subtask 24-23-51-210-060
B. Do a check of APU Oil Filters
(1)
Replace the APU oil system filters if you find metal contamination:
-
for APU GTCP 36-300 (Ref. TASK 49-91-41-200-001) and (Ref. TASK 49-91-45-200-002)
-
for APU APS3200 (Ref. TASK 49-91-41-920-001) and (Ref. TASK 49-91-41-920-002)
-
for APU 131-9(A)
(Ref. TASK 49-91-41-200-002)
(2)
Change the oil if you find metal contamination:
-
for APU GTCP 36-300
(Ref. TASK 49-90-00-600-002)
-
for APU APS3200
(Ref. TASK 49-90-00-600-005)
-
for APU 131-9(A)
(Ref. TASK 49-90-00-600-008)
1EFF : ALL 1 24-23-51Page 419 1 1 May 01/05R 1 1 1CES 1
TASK 24-23-51-400-001
Installation of the APU Generator 8XS
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific Torque Wrench : range 2.00 to 26.00 lbf.ft
(0.20 to 3.60 m.daN) R No specific Torque Wrench : range 0.00 to 1.20 m.daN R (0.00 to 9.00 lbf.ft)
No specific Torque Wrench : range 0.20 to 3.60 m.daN
(2.00 to 26.00 lbf.ft) No specific Torque Wrench : range 1.00 to 10.00 m.daN
(8.00 to 75.00 lbf.ft) FRDH141 1 ADAPTER - TORQUE 98D49207537001 1 CABLE - SAFETY, APU GENERATOR
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific lockwire-corrosion resistant steel 0.8 mm (0.0314 in.) dia
Material No. 03-002 GB DEF-STAN 91-101
LUBRICATING OIL TURBINE ENGINE SYNT BASE
(Ref. 20-31-00)
Material No. 07-020 AI TNA 007-10012
IDENTIFICATION PAINT (Ref. 20-31-00)
Material No. 11-004 USA MIL-T-81533
1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
(Ref. 20-31-00)
C. Expendable Parts
-------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
7 seal plate
9 seal
9 seal
10 packing
13 sealwasher
D. Referenced Information
24-23-04 01 -04024-23-51 01 -01024-23-51 01 -010A24-23-51 01 -02024-23-51 01 -040
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
20-21-11-911-001 Tightening Torques for Standard Threaded Fasteners
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action
49-00-00-860-003 APU Start by External Power (GTCP 36-300)
49-00-00-860-004 APU Shutdown by External Power (GTCP 36-300)
49-00-00-860-005 APU Start by External Power (APS 3200)
49-00-00-860-006 APU Shutdown by External Power (APS 3200)
49-00-00-860-008 APU Start by External Power (131-9(A))
49-00-00-860-009 APU Shutdown by External Power (131-9(A))
49-90-00-600-001 Check Oil Level and Replenish (GTCP 36-300)