 (d) Electrical Generation Interface Unit (EGIU) The main function of this unit is to provide main electrical parameters to the SDACS via ARINC 429 data links. Two identical EGIU's are used per aircraft. One consists of 2 isolated channels: (Ref. Fig. 005)
 -
Channel 1 is allocated to IDG1 or IDG2,

 -
Channel 2 is allocated to APU Generator or External Power (EXT PWR).

 


 Electrical Generation Interface Unit - Schematic Diagram
 Figure 005

R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 24-22-00Page 37/38 1201-299, 301-399, 1Aug 01/05 1 1 1CES


 The information provided to the SDACs is as follows:
 - POR voltage (phase A),
 - Load (phase A),
 - Line Frequency (phase A),
 - Oil Inlet/Outlet Temperature,
 - Overload,
 - Generator Fault,
 - IDG Disconnect Status,
 - IDG Low Oil Pressure,
 - External Power available,
 - External Power ON. 
R  **ON A/C 401-499, 
R  (c) Maintenance BITE 
R  The maintenance BITE is intended to operate with the relevant 
R  generator not running. The maintenance BITE is executed only, 
R  upon command from the GAPCU. The GAPCU only requests the 
R  maintenance BITE if requested by the Centralized Fault Display 
R  Interface Unit (CFDIU). 
R  For more details, refer to 24-41-00 Para. BITE Test. 
R  (d) Communication between the GCU and the SDAC 
R  The other functions on the GCU is to provide main electrical 
R  parameters to the SDACS via ARINC 429 data links. 
R  The infomation provided to the SDACs is as follows: 
R  - POR voltage (phase A), 
R  - Load (phase A), 
R  - Line Frequency (phase A), 
R  - Oil Inlet/Outlet Temperature, 
R  - Overload, 
R  - Generator Fault, 
R  - IDG Disconnect Status, 
R  - IDG Low Oil Pressure.

 


R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 Analog and discrete input parameters are listed below: Channel 1: Analog and Discrete Input Parameters
 -------------------------------------------------------------------------------| PARAMETER DEFINITION |IDG1|IDG2| STATE | COMMENTS | |-----------------------------|----|----|-------------|-----------------------| | POR VOLTAGE 115 VAC, 400 Hz | X | X | | Parameter for defini- | | (PHASE A) | | | | tion of AC voltage | | | | | | and frequency | |-----------------------------|----|----|-------------|-----------------------| | AC LOAD | X | X | | | | | | | | | |-----------------------------|----|----|-------------|-----------------------| | IDG OIL INLET TEMPERATURE | X | X | | | | | | | | | |-----------------------------|----|----|-------------|-----------------------| | IDG OIL OUTLET TEMPERATURE | X | X | | | | | | | | | |-----------------------------|----|----|-------------|-----------------------| | OVERLOAD WARNING | X | X | Ground when | | | | | | overload | | |-----------------------------|----|----|-------------|-----------------------| | GENERATOR FAULT | X | X | 28 VDC when | | | | | | FAULT | | |-----------------------------|----|----|-------------|-----------------------| | IDG DISC. STATUS | X | X | Ground when | | | | | | DISC | | |-----------------------------|----|----|-------------|-----------------------| | IDG DISC P/BSW POS | X | X | Ground when | From P/BSW contact | | | | | ON | relay | |-----------------------------|----|----|-------------|-----------------------| | IDG OIL LOW PRESSURE | X | X | Ground when | From IDG low pressure | | | | | low pressure| switch | | | | | | | | | | | | | |-----------------------------|----|----|-------------|-----------------------| | GEN P/BSW POSITION | X | X | 28 VDC when | From GCU TR source | | | | | ON | (through PR) | -------------------------------------------------------------------------------
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 24-22-00Page 40 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1


R  **ON A/C 401-499, 
R  Analog and discrete input parameters are listed below: 
R  -------------------------------------------------------------------------------
R  | PARAMETER DEFINITION |IDG1|IDG2| STATE | COMMENTS | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | POR VOLTAGE 115 VAC, 400 Hz | X | X | | Parameter for defini- | 
R  | (PHASE A) | | | | tion of AC voltage | 
R  | | | | | and frequency | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | AC LOAD | X | X | | | 
 