• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:13来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  | | | | | | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | IDG OIL INLET TEMPERATURE | X | X | | | 
R  | | | | | | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | IDG OIL OUTLET TEMPERATURE | X | X | | | 
R  | | | | | | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | OVERLOAD WARNING | X | X | Ground when | | 
R  | | | | overload | | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | GENERATOR FAULT | X | X | 28 VDC when | | 
R  | | | | FAULT | | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | IDG DISC. STATUS | X | X | Ground when | | 
R  | | | | DISC | | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | IDG DISC P/BSW POS | X | X | Ground when | From P/BSW contact | 
R  | | | | ON | relay | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | IDG OIL LOW PRESSURE | X | X | Ground when | From IDG low pressure | 
R  | | | | low pressure| switch | 
R  | | | | | | 
R  | | | | | | 
R  |-----------------------------|----|----|-------------|-----------------------| 
R  | GEN P/BSW POSITION | X | X | 28 VDC when | From GCU TR source | 
R  | | | | ON | (through PR) | 
R  -------------------------------------------------------------------------------

R 1EFF : 401-499, 1 24-22-00Page 41 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,

 

 Channel 2: Analog and Discrete Input Parameters
 -------------------------------------------------------------------------------
| PARAMETER DEFINITION | EXT| APU| STATE | COMMENTS |
 | | PWR| | | |
 |-----------------------------|----|----|-------------|-----------------------|
 | POR VOLTAGE 115VAC 400 Hz | X | X | | Parameter for defini- |
 | (PHASE A) | | | | tion of AC voltage |
 | | | | | and frequency |
 |-----------------------------|----|----|-------------|-----------------------|
 | AC LOAD | | X | | |
 | | | | | |
 |-----------------------------|----|----|-------------|-----------------------|
 | OVERLOAD WARNING | | X | Ground when | |
 | | | | overload | |
 |-----------------------------|----|----|-------------|-----------------------|
 | GENERATOR FAULT | | X | 28 VDC when | From aircraft 28 VDC |
 | | | | FAULT | (through power ready) |
 |-----------------------------|----|----|-------------|-----------------------|
 | GEN P/BSW POSITIOM | | X | 28 VDC when | From GCU TR source |
 | | | | ON | (through PR) |
 |-----------------------------|----|----|-------------|-----------------------|
 | EXT PWR AVAILABLE | X | | 28 VDC when | |
 | | | | available | |
 |-----------------------------|----|----|-------------|-----------------------|
 | Class II FAILURE | X | | Ground when | |
 | | | | message | |
 |-----------------------------|----|----|-------------|-----------------------|
 | EXT PWR ON | X | | Ground when | |
 | | | | ON | |
 -------------------------------------------------------------------------------
Channel 2: Flip-Flop Circuit
 -------------------------------------------------------------------------------| INPUT | STATE | COMMENTS | |---------------------------------------|-------------|-----------------------| | 28 VDC VIA EXT PWR P/BSW | 28 VDC when | | | | P/BSW ON | | -------------------------------------------------------------------------------
Each EGIU includes a one shot circuit controlled by EXT PWR pushbutton switch allowing to latch the EPC auxiliary relay. This device is located on channel 2 of EGIU.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 24-22-00Page 42 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1


 (Ref. Fig. 006)
 The supply of each channel of the unit is provided:

 -either by 28 V back-up (from busbar 3PP),
 - or by 28 VDC delivered by the associated control unit (GCU or

 GPCU). A 5 VDC supply is provided to the FAULT legend of the GEN pushbutton switches.
 B. System Data Acquisition Concentrator (SDAC) Communications
 (Ref. Fig. 007)
 Each EGIU channel interfaces with each SDAC via a single ARINC 429 data
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM ELECTRICAL POWER 电源1(103)