GLC-1 Supply - Schematic Diagram
Figure 011
1EFF : 001-049, 051-099, 101-149, 151-199, 1 24-22-00Page 71/72 1201-299, 301-399, 1Aug 01/05 1 1 1CES R **ON A/C 401-499,
R (Ref. Fig. 011A)
R **ON A/C ALL
The operation of each generator is controlled by the GEN1 (2) pushbutton
switch.
This pushbutton switch has two stable positions:
-OFF selected, the pushbutton switch is released and the white OFF legend is on. The generator is shut down (de-energized) and the line contactor (GLC) is open,
-when the pushbutton switch is pressed in, the generator is energized, its rotational speed being high enough. If the electrical parameters are correct, the line contactor closes. Then, the generator supplies its network.
When a fault is detected:
-the GCU protections are activated (PR opening),
-FAULT legend comes on on GEN pushbutton switch (accompanied by the
single chime and MASTER CAUT light). (Ref. Fig. 012) At the same time: - on the upper display unit of the ECAM system, an amber message is
displayed, - on the lower display unit, the ELEC page is automatically displayed. Simultaneously, the automatic transfer becomes effective:
-the lost network is supplied by another power source available. The crew has to release-out GEN pushbutton switch (white OFF legend comes on on GEN pushbutton switch).
NOTE : FAULT legend comes on on GEN pushbutton switch also when GLC is
____ open. When starting engine 1, GEN 1 OFF warning is displayed on the ECAM display unit if generator 1 is not on line: (Ref. Fig. 013) Similarly, when starting engine 2, GEN 2 OFF warning is displayed on the ECAM display unit if generator 2 is not in line: (Ref. Fig. 014)
B. Transfer Circuit The transfer circuit enables supply of both or either AC electrical network(s) from one of the four power sources (GEN 1, GEN 2, APU GEN, EXT PWR). This is via the transfer contactors (BTC). The BTC control is entirely automatic. It depends on the availability of these sources and the correct condition of each network. The BTC 1 closes if no interlock condition exists on GCU 1:
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
(Ref. Fig. 015)
R **ON A/C 401-499,
R (Ref. Fig. 015A)
**ON A/C 001-049, 051-060, 101-102, 201-201,
- when generator 1 is not available, in order to supply network 1 from another power source (generator 2, auxiliary generator or ground power unit), - to supply network 2 from generator 1 in case of non-availability of: generator 2, auxiliary generator, and electrical ground power unit.
R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,
- when generator 1 is not available, in order to supply network 1 from another power source (generator 2, auxiliary generator or ground power unit), - to supply network 2 from generator 1 in case of non-availability of: generator 2, auxiliary generator, and electrical ground power unit. In case of single generator configuration, the sheddable busbars 218XP, 220XP, 210PP and 212PP are no longer available.
R GLC-1 Supply - Schematic Diagram R Figure 011A
1EFF : 401-499, 1 24-22-00Page 75/76 1 1 Aug 01/05 1 1 1CES
INTENTIONALLY BLANK
1 1
24-22-00Page 77
1 1 Aug 01/05 1 1 1CES 1
GEN 1 FAULT - Upper and Lower ECAM Display Unit
Figure 012 (SHEET 1)
1EFF : ALL 1 24-22-00 Page 78
1 1 Aug 01/05
1 1
1CES 1
GEN 1 FAULT - Upper and Lower ECAM Display Unit
Figure 012 (SHEET 2)
1EFF : ALL 1 24-22-00 Page 79
1 1 Aug 01/05
1 1
1CES 1
GEN 1 FAULT - Upper and Lower ECAM Display Unit
Figure 012 (SHEET 3)
1EFF : ALL 1 24-22-00 Page 80
1 1 Aug 01/05
1 1
1CES 1
INTENTIONALLY BLANK
1 1
24-22-00Page 81
1 1 Aug 01/05 1 1 1CES 1
GEN 1 OFF - Upper and Lower ECAM Display Unit
Figure 013 (SHEET 1)
1EFF : ALL 1 24-22-00 Page 82
1 1 Aug 01/05
1 1
1CES 1
GEN 1 OFF - Upper and Lower ECAM Display Unit
Figure 013 (SHEET 2)
1EFF : ALL 1 24-22-00 Page 83