Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power Fig. 405
R (1) Make sure that the access platform is in position at the cargo R compartment door 825AR.
R (2) Make sure that the cargo compartment door 825AR is open.
R (3) In the zone 130, make sure that the ceiling panels 131MC, 131NC,
R 131PC are removed.

R Subtask 24-22-17-010-057

R B. Get Access
R FOR 51XU1, 51XU2
R (1) Make sure that the access platform is in position at the access door


R 822.

 

R  (2) Make sure that the access door 822 is open. 
R  Subtask 24-22-17-860-059 
R  C. Aircraft Maintenance Configuration 
R  (1) Make sure that the external power connector is not connected to the 
R  aircraft external power receptacle. 
R  (2) FOR 41XU1, 41XU2, 51XU1, 51XU2 
R  Make sure that the warning notice(s) is (are) in position on the 
R  access door 121AL to tell persons not to connect the external power 
R  connector to the aircraft external power receptacle. 
R  (3) In the cockpit, on the ELEC panel 35VU, make sure that these 
R  pushbutton switches are released: 
R  - BAT1, BAT2, 
R  - APU GEN, 
R  - GEN1, GEN2, 
R  - EXT PWR. 
R  (4) In the cockpit, make sure that the warning notice(s) is (are) in 
R  position to tell persons not to operate the pushbutton switches on 
R  these overhead panels: 
R  - 21VU (EMER ELEC PWR section), 
R  - 25VU (APU section), 
R  - 35VU (ELEC). 
R  4. Procedure_________ 
R  (Ref. Fig. 401A/TASK 24-22-17-991-001-A) 
R  Subtask 24-22-17-420-053 
R  A. Installation of the AC Current Transformer 
R  FOR 41XU1, 41XU2 
R  (Ref. Fig. 402/TASK 24-22-17-991-002) 
R  (1) Put the disconnected cables (3) and (4) through the current 
R  transformer (10). 
R  NOTE : Make sure that the location of the cables agrees with that you____ 
R  recorded at the removal. 
R  (2) Move the current transformer (10) along the cables.

 

R  (3) Install the washers (9) and the screws (8) on the current transformer 
R  (10) and tighten them. 
R  (4) Remove the blanking caps from the electrical connectors. 
R  (5) Make sure that the electrical connectors are clean and in the correct 
R  condition. 
R  (6) Connect the electrical connector (11) to the current transformer 
R  (10). 
R  (7) Install the cables (3) and (4), the washers (2) and the nuts (1) on 
R  the studs of the terminal block (5) and tighten them. 
R  NOTE : Make sure that the location of the cables agrees with that you____ 
R  recorded at the removal. 
R  (8) Install the cover (7) and the screws (6) on the terminal block (5). 
R  Tighten the screws (6). 
R  Subtask 24-22-17-420-054 
R  B. Installation of the AC Current Transformer 
R  FOR 51XU1, 51XU2 
R  (Ref. Fig. 405/TASK 24-22-17-991-005) 
R  (1) Put the disconnect cables through the current transformer (1). 
R  NOTE : Make sure that the location and the color of the cables of____ 
R  each bundle agree with those you recorded at the removal. 
R  (2) Move the current transformer (1) along the cable bundles. 
R  (3) Install the screws (2) and (4) and the nuts (5) and (6) on the 
R  current transformer (1) and tighten them. 
R  (4) Remove the blanking caps from the electrical connectors. 
R  (5) Make sure that the electrical connectors are clean and in the correct 
R  condition. 
R  (6) Connect the electrical connector (3) to the current transformer (1). 
R  (7) Install new cable ties. 
R  (8) Connect the cables (12) to the studs of the module 30XN1 (30XN2).

 

R  (9) Install the washers (11) and the nuts (10) on the studs of the module 
R  30XN1 (30XN2). 
R  (10) TORQUE the nut to between 1.25 and 1.35 m.daN (110.61 and 119.46 
R  lbf.in). 
R  (11) Connect the cables (9) to the studs of the module 30XN1 (30XN2). 
R  (12) Install the washers (8) and the screws (7) on the studs of the module 
 