R  **ON A/C 106-149, 151-199, 204-299, 301-399, 401-499,
 (b) CSM/G control logic 3 different logics control energization of the emergency generation: - the automatic electrical logic: this is identical to that of the RAT extension, - the manual electrical logic: this is identical to that of the RAT extension, - the electrical test logic: this simulates the automatic electrical logic because it allows the emergency generator to be coupled to the Blue hydraulic system (supplied by the hydraulic electric pump) while inhibiting RAT extension.
 **ON A/C ALL
 (3) Controls and indications in the cockpit
 **ON A/C 001-049, 051-099, 101-105, 201-203,
 (Ref. Fig. 008) 
R  **ON A/C 106-149,
 (Ref. Fig. 008A) 
R  **ON A/C 151-199, 204-299, 301-302,
 (Ref. Fig. 008B) 
R  **ON A/C 303-399, 401-499, 
R  (Ref. Fig. 008C)

 

 **ON A/C ALL
 (a) The RAT and CSM/G are:
 -automatically controlled by AC BUS 1 and AC BUS 2 loss and V > 100 kts,
 - or manually by means of the EMER ELEC PWR/MAN ON guarded pushbutton switch on the EMER ELEC PWR section of the overhead panel 21VU.
 When a failure of the AC BUS 1 and 2 occurs, simultaneously:
 -
the RAT is automatically extended,

 -
the emergency generator is automatically coupled to AC and DC ESS busbars,

 -
the red FAULT legend comes on on RAT & EMER GEN annunciator


 until the emergency generator is available. In all cases, the pilot has to press EMER ELEC PWR/MAN ON pushbutton switch in order to confirm the automatic logic. Red FAULT legend disappears if coupling is obtained.
 (b) A test of the emergency generator can be initiated on the ground. The procedure is controlled by the EMER GEN TEST pushbutton switch located on the EMER ELEC PWR section of overhead panel 21VU. When EMER GEN TEST pushbutton switch is pressed and held:
 -ELEC page is automatically displayed on the ECAM system (on ground only),
 -the emergency generator is coupled to its network,
 -DC ESS BUS SPLY and AC ESS BUS switching line contactors (4PC/3XC) open, isolating AC and DC essential busses,
 - on the ECAM system: green lines between normal busbars and essential busbar disappear. The white EMER GEN, ESS TR and the green indications of the corresponding parameters appear, green lines between EMER GEN and AC ESS and DC ESS appear.
 NOTE : The ELEC page must disappear when the EMER GEN TEST
____
 pushbutton switch is released.

 (c) A test of the emergency GCU can be initiated on the ground from the CFDS. The emergency GCU is a type 3 system:
 i.e. it has neither an input bus nor an output bus, it is
 connected to CFDIU by 2 discrete links.
 The test procedure is described in
 (Ref. Fig. 009)

 1EFF : ALL 1 24-24-00Page 18 1 1 May 01/05R 1 1 1CES 1


 Electrical Emergency Generation System - Control System
 Figure 008

R 1EFF : 001-049, 051-099, 101-105, 201-203, 1 24-24-00Page 19/20 1 1 May 01/05 1 1 1CES
1


 INTENTIONALLY BLANK


R 1 1


24-24-00Page 21
1 1 Aug 01/05 1 1 1CES 1R Electrical Emergengy Generation System - Control System R Figure 008A (SHEET 1)


 1EFF : 106-149, 1 24-24-00Page 22 1 1 Aug 01/05 1 1 1CES 1R Electrical Emergengy Generation System - Control System R Figure 008A (SHEET 2)


R 1EFF : 106-149, 1 24-24-00Page 23 1 1 Aug 01/05 1 1 1CES 1


 INTENTIONALLY BLANK

R 1 1


24-24-00Page 24
1 1 Aug 01/05 1 1 1CES 1


 Electrical Emergency Generation System - Control System R Figure 008B
R 1EFF : 151-199, 204-299, 301-302, 1 24-24-00Page 25/26 1 1 Aug 01/05 1 1 1CES


 INTENTIONALLY BLANK

R 1 1


24-24-00Page 27
1 1 Aug 01/05 1 1 1CES 1


 Electrical Emergency Generation System - Control System R Figure 008C (SHEET 1)
R 1EFF : 303-399, 401-499, 1 24-24-00Page 28 1 1 Aug 01/05 1 1 1CES 1


 Electrical Emergency Generation System - Control System R Figure 008C (SHEET 2)
R 1EFF : 303-399, 401-499, 1 24-24-00Page 29 1 1 Aug 01/05 1 1 1CES 1


 Test Procedure for GCU EMER by MCDU Figure 009 
R 1EFF : 1 1 1CES  ALL  1 111 24-24-00 Page 30 Aug 01/05

 

 B. Electrical Emergency Configuration NOTE : For more data, REF.31-67-24.____ **ON A/C 001-049, 051-099, 101-105, 201-203,
R  (Ref. Fig. 010) **ON A/C 106-149, 151-199, 204-299, 301-399, 401-499,
 (Ref. Fig. 010A) **ON A/C 001-049, 051-099, 101-105, 201-203,
R  (1) Electrical emergency configuration during RAT extension (<10 sec) and in landing gear extended configuration (Ref. Fig. 011) **ON A/C 106-149, 151-199, 204-299, 301-399, 401-499,
 