• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-09 10:26来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 A.  General
 WARNING: STATIC ELECTRICAL SHOCK HAZARD MAY EXIST IF THE AIRPLANE MEETS
_______ THE TEST REQUIREMENTS. MAKE SURE THE AIRPLANE HAS SUFFICIENT ELECTRICAL BONDING BEFORE DOING MAINTENANCE.
 (1)  
Do this check when the usual procedure to refuel the airplane does not attach the static ground cable to the earth-ground facility connection point. Do not use this procedure to check the electrical bonding of airplane components.

 B.  
Parts

 (1)  
Low Resistance Ohmmeter

 C.  
References

 (1)  
AIPC 24-41-03, Fig. 1

 (2)  
AMM 24-22-00/201, Manual Control

 (3)  
SSM 24-41-01, SSM 24-41-02

 (4)  
WDM 24-41-13, WDM 24-41-23

 D.  
Access

 (1)  
Location Zone 118 Electrical and Electronics Compartment, RH 715 Nose Landing Gear

 (2)  
Access Panel
 118A External Power Receptacle Door


 E.  
Procedure


 S 766-021
 (1)  
Prepare to check the continuity between the receptacle neutral pins and the grounding stud.

 (a)  
Remove electrical power from the airplane (AMM 24-22-00/201).

 (b)  
Open the door 118A for the external power receptacle.


 S 766-022
 (2)  
Check the continuity between the receptacle neutral pins and the grounding stud.

 (a)  
Use the low resistance ohmmeter to measure the resistance from the neutral pins on the receptacles to the nose gear grounding stud.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-41-03
 ALL  ú ú 01 Page 605 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

747-400 MAINTENANCE MANUAL
SEE B
SEE A
EXTERNAL POWER RECEPTACLE NO. 2, D52 EXTERNAL POWER RECEPTACLE DOOR
EXTERNAL POWER
NRECEPTACLE NNO. 1, D51
GROUNDING LUG 
NEUTRAL PINS  FWD 
A EXTERNAL POWER RECEPTACLE, P36 

FWD
NOSE GEAR SHOCK STRUT
B
Neutral Pin to Grounding Stud
Continuity Check
Figure 602

D20915
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-41-03
 ALL  ú ú 01 Page 606 ú Feb 10/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (b)  
Make sure the resistance does not exceed 0.1 ohms.

 (c)  
If the resistance exceeds 0.1 ohms, do these tasks:
 1) "External Power Receptacle Pin Visual Inspection"
 (AMM 24-41-03/601).


 2)  "External Power Receptacle Pin Inspection" (AMM 24-41-03/601).

 (d)  
If the problem continues, examine and repair the wiring between the external power receptacle neutral pins and the associated ground stud.


 S 946-023
 (3)  
Put the Airplane back to its usual condition.

 (4)  
Close the door 118A for the receptacles.


 S 946-024
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-41-03
 ALL  ú ú 02 Page 607 ú Jun 10/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 EXTERNAL POWER CONTACTOR - REMOVAL/INSTALLATION
_______________________________________________
 1.  General_______
 A.  This procedure has two tasks. One task is the removal of the external power contactors (R12 and R13). The other task is the installation of the external power contactors.
 B.  The installation task includes an operational test of the external power contactors.
 C.  The external power contactor R12 is installed in the P714 auxiliary/external No. 1 power center. The external power contactor R13 is installed in the P715 auxiliary/external No. 2 power center. The P714 and P715 power centers are in the E/E compartment.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(95)