24-41-00
ALL ú ú 03 Page 1 ú Feb 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
SEE A
SEE B
ELECTRICAL SYSTEM CONTROL MODULE
A
POWER NOT IN
USE LIGHTS AC CONNECTED
AC CONNECTED LIGHT
LIGHT
FWD
EXTERNAL POWER EXTERNAL POWER EXTERNAL POWER
RECEPTACLE RECEPTACLE RECEPTACLE DOOR
NO. 1 NO. 2
EXTERNAL POWER RECEPTACLES B
Electrical System Control Module/External Power Receptacle Location
Figure 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
24-41-00
ALL ú ú 01 Page 2 ú Feb 10/89
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
4. Ground Power Current Transformer (Fig. 2)
________________________________
A. There are two ground power current transformers (GPCTs), one for each input of the external power. The three-phase ac feeder lines are routed through the large holes in the GPCT and become the primary winding for each GPCT core. The GPCT provides current monitoring input to the BCUs. The GPCTs are located in the main equipment center in the P714 and P715 panels.
5. External Power Contactors (Fig. 2)
_________________________
A. There are two external power contactors (XPC) used to connect external power with the airplane sync bus. The contactors are located in the main equipment center. The contactor for external power receptacle No. 1 is located in P714. The contactor for external power receptacle No. 2 is located in P715.
B. The XPC is an electrically held three-phase contactor. The XPC main contacts are rated at 115/200 volts, 400 Hz, and 260 amps per phase for continuous operation. The XPC main contacts connect the external power source to the sync bus when closed. The BCUs provide the control for their associated XPC in conjunction with manual operation of the external power switch on the overhead panel.
C. The XPC has the capability of interrupting, without damage, a signal phase or multiphase fault current of 2000 amps.
D. The XPC has five normally open and nine normally closed auxiliary contacts which operate in unison with the main contacts. The auxiliary contacts are rated for an inductive load of 1 amp at 240 volts ac, and