• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-09 10:26来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

FUNCTION FAULT DIFFERENTIAL SYNC BUS  SENSING 3 PHASE SYNC BUS DPCT  THRESHOLD 30 |5 AMPS  DELAY TIME MSEC 155 |5  TRIPS XPC, APB, BTBs ADJACENT SSB,  REMARKS 
SYNC BUS REDUNDANT FAULT DIFFERENTIAL  3 PHASE SYNC BUS DPCT  30 |5 AMPS  MSEC 130 |10  BTBs ADJACENT SSB,  HAS FAILED ACTIVE ONLY WHEN THE CPU 
INTLK EXT PWR  PIN "F" PIN "E"  CONTACTS INTERNAL XPC 
UNLIKE SOURCE (SUSP) PARALLEL SUSTAINED  SSB BTBs GCBs APBs XPCs POSITION OF:  SOURCES BETWEEN UNLIKE PARALLELING  MSEC 135 |15  ARE POWERS AUX IDG'S OR ARE BTB - IF POWER IN-VOLVED) INVOLVED (NO IDG APB - IF EXT AND INVOLVED XPC AND2. ADJACENT1.  RECLOSED SOURCE MUST BE MANUALLY ARE TRIPPED, THE SELECTED AFTER BOTH THE XPC AND APB 
CPU FAILURE  FAILURE WATCHDOG TIMERS SUPPLIES CPU POWER  SOFTWARE ERRORS FAILURES SUPPLIES ON CPU POWER  XPC, APB, GSSR, GSTR, GHRs 

Bus Control Unit (BCU) Protective Functions
Figure 6 (Sheet 2)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-23-00
 ALL  ú ú 05 Page 19 ú Jun 10/89
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 b) APU Power Ready signal is present. c) Actuation of the APU GEN switch has been sensed.
 2)  The BCU will send a remote APB close signal to the AGCU when the airplane is in ground mode and the following conditions are all true: a) APB is open. b) APU Power Ready signal is present. c) Actuation of the APU GEN switch has been sensed. d) Auto Parallel Ready signal is present.
 3)  The BCU will send a remote APB trip signal to the AGCU and an APB trip command to the APB when any of the following are true: a) AGCR is commanded to trip by the BCU. b) APB SUSP command is present. c) Synchronizing bus fault protection signal is present. d) Transfer from auxiliary power to IDG power is complete. e) Transfer from auxiliary power to external power is
 complete. f) Actuation of the APU GEN switch when the APB is closed.
 (d)  The BCU provides the interface between the EXT PWR switch and the XPC. The BCU can also trip the XPC as part of the control and protection function. 1) The BCU will send a continuous XPC close command to the XPC
 if the following conditions are all true:
 a) Actuation of the EXT PWR switch has been sensed.
 b) Airplane is in ground mode.
 c) External power AVAIL signal is present.
 d) XPC is open.

 2)  The BCU will remove the XPC close command to the XPC if any of the following conditions are true: a) External power plug is disconnected. b) External power protective trip occurs. c) Actuation of the EXT PWR switch has been sensed and the
 XPC is closed.
 d) Transfer to IDG power is complete.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 24-23-00
 ALL  ú ú 05 Page 20 ú Jun 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 e) Transfer to auxiliary power is complete.
 f) XPC SUSP command is present.
 g) Synchronizing bus fault protection signal is present.

 (e)  The BCU provides the interface between the ground service switch and the GSSR and GSTR. When external power or auxiliary power are not available, the GSSR will not be energized (Ref 24-50-00). 1) The BCU will command the GSSR and GSTR to close and supply
 the ground service bus with external power when the
 following conditions are all true:
 a) Ground service switch is actuated.
 b) Airplane is in ground mode.
 c) AC Bus 1 is not powered.
 d) External power is available.

 2)  The BCU will command the GSTR to close and supply the ground service bus with auxiliary power when the following conditions are all true: a) Ground service switch is actuated. b) Airplane is in ground mode. c) AC Bus 1 is not powered. d) External power is not available. e) APU power ready signal is available.
 3)  The BCU will remove the GSTR and GSSR close command and supply the ground service bus with AC Bus 1 power when one of the following conditions are true: a) AC Bus 1 becomes powered. b) Ground service switch is actuated. c) External power plug is disconnected. d) XPC trip is present.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 ELECTRICAL POWER 电源 2(11)